Technical datasheet: PW 6207 D
10 002 290 / 01
13
KW
Cold water
(Soft water)
Water pressure/Min. flow rate
14.5 psi
100 kPa
Water pressure/Max. flow rate
145 psi
1000 kPa
Max. volume flow
6.87 gal/min
26 l/min
Max. volume flow in absence of hot and hard water
supply
11.1 gal/min
42 l/min
2 Connector hoses with threaded joint 3/4” including
Y fitting (3/4” / 1”) included with the unit.
Threaded connector fitting at site as per DIN 44 991
(flat sealing)
1" external thread
Length of connection hose
59 1/16"
1500 mm
Average water requirement for a standard program
(60°C colored washing) determined at cold, hot and
hard water connection.
approx. 32.8 gal/h
approx. 124 l/h
Add the hot water water requirement to the cold
water requirement, if there is no hot water supply
available.
If connecting to industrial water supply (optional),
subtract that water requirement from the cold water
requirement.
WW
Hot water
(Soft water)
Max. temperature
158°F
70°C
Min. flow pressure
14.5 psi
100 kPa
Max. pressure
145.04 psi
1000 kPa
Max. throughput
4.22 gal/min
16 l/min
On-site connection thread according to DIN 44 991
3/4" external thread
Length of connection hose
(supplied) 1 connection hose)
59 1/16"
1500 mm
Water requirements (average for 60°C
programme)
approx. 28.5 gal /h
approx. 108 l/h
Machine can be connected to a hot water supply
line with a temperature of 70°C to max. 85°C. This
requires a separate inlet hose. This additional inlet
hose is available from Miele Spares. The machine
must also be reprogrammed by Miele Service or an
authorised agent.
If hot water is not available, connect hot water hose
to cold water valve!
KWH
Cold water
Water pressure/Min. flow rate
14.5 psi
100 kPa
(Hard water)
Water pressure/Max. flow rate
145.04 psi
1000 kPa
Max. volume flow
8.45 gal/min
32 l/min
Threaded connector fitting at site as per DIN 44 991
(flat sealing)
1" external thread
Length of connector hose
59 1/16"
1500 mm
Avarage water requirement for a standard program
(60° colored washing) determined at cold, hot and
hard water connection
approx. 19.5 gal/h
approx. 74 l/h
KWF
Cold Water
(
Liquid
dispensing
)
Water pressure/Min. flow rate
14.5 psi
100 kPa
Water pressure/Max. flow rate
145.04 psi
1000 kPa
Max. volume flow
1.45 gal/min
5.5 l/min
1 Connector hose with threaded joint 3/4” optionally
included with the unit.
Threaded connector fitting at site as per DIN 44991
(flat sealing)
3/4" external thread
Length of connector hose
59 1/16"
1500 mm
AV
Drainage
Max. water outflow temperature
203 °F
95°C
Dump valve
Drainage supports in machine (outer diameter)
2
15
/
16
"
75 mm [DN 70]
On-site drain connection (inner diameter)
2
15
/
16
"
75 mm [DN 70]
Max. transient throughput
52.8 gal/min
200 l/min
Vented drainage required. If ventilation is
insufficient, fit Miele kit, Mat. no. 05238090.
Drain manifolds serving several machines must be
of sufficient cross-section.
Fittings
Without base
It is essential to ensure that the appliance is
fastened adequately to the floor!
Fastening material included with unit:
2 x mounting brackets (from transport lock)
2 x wood screws DIN 571 (Ø x length)
8 mm x 80 mm
2 x screw anchors (Ø x length)
5/16" x 3
1
/
8
"
1/2" x 2 3/
8
"
12 mm x 60 mm
A sufficiently firm floor with sufficient load-bearing
capacity is necessary for the installation. The
fastening material included is only suitable for a
solid concrete floor. The fastening material for other
suitable floor types must be provided on site.
B
Summary of Contents for PW 6207 D
Page 3: ...10 002 290 01 3 Machine dimensions measurements in millimeters ...
Page 4: ...4 10 002 290 01 Connections measurements in millimeters ...
Page 5: ...10 002 290 01 5 Machine dimensions measurements in millimeters ...
Page 6: ...6 10 002 290 01 Machine dimensions measurements in millimeters ...
Page 7: ...10 002 290 01 7 Machine dimensions measurements in inches ...
Page 8: ...8 10 002 290 01 Connections measurements in inches ...
Page 9: ...10 002 290 01 9 Machine dimensions measurements in inches ...
Page 10: ...10 10 002 290 01 Machine dimensions measurements in inches ...