background image

Technical datasheet: PW 6207 D 

10 002 290 / 01 

13 

KW

 

Cold water

(Soft water) 

Water pressure/Min. flow rate 

14.5 psi 

100 kPa 

Water pressure/Max. flow rate 

145 psi 

1000 kPa 

Max. volume flow 

6.87 gal/min 

26 l/min 

Max. volume flow in absence of hot and hard water 
supply 

11.1 gal/min 

42 l/min 

2 Connector hoses with threaded joint 3/4” including 
Y fitting (3/4” / 1”) included with the unit. 

Threaded connector fitting at site as per DIN 44 991 
(flat sealing) 

1" external thread 

Length of connection hose  

59 1/16" 

1500 mm 

Average water requirement for a standard program 
(60°C colored washing) determined at cold, hot and 
hard water connection. 

approx. 32.8 gal/h 

approx. 124 l/h 

Add the hot water water requirement to the cold 
water requirement, if there is no hot water supply 
available. 
If connecting to industrial water supply (optional), 
subtract that water requirement from the cold water 
requirement. 

WW

 

Hot water

(Soft water) 

Max. temperature 

158°F 

70°C 

Min. flow pressure 

14.5 psi 

100 kPa 

Max. pressure 

145.04 psi 

1000 kPa 

Max. throughput  

4.22 gal/min 

16 l/min 

On-site connection thread according to DIN 44 991 

3/4" external thread 

Length of connection hose  
(supplied) 1 connection hose) 

59 1/16" 

1500 mm 

Water requirements (average for 60°C 

programme) 

approx. 28.5 gal /h 

approx. 108 l/h 

Machine can be connected to a hot water supply 
line with a temperature of 70°C to max. 85°C. This 
requires a separate inlet hose. This additional inlet 
hose is available from Miele Spares. The machine 
must also be reprogrammed by Miele Service or an 
authorised agent. 
If hot water is not available, connect hot water hose 
to cold water valve! 

KWH 

Cold water

Water pressure/Min. flow rate 

14.5 psi 

100 kPa 

(Hard water) 

Water pressure/Max. flow rate 

145.04 psi 

1000 kPa 

Max. volume flow 

8.45 gal/min 

32 l/min 

Threaded connector fitting at site as per DIN 44 991 
(flat sealing) 

1" external thread 

Length of connector hose 

59 1/16" 

1500 mm 

Avarage water requirement for a standard program 
(60° colored washing) determined at cold, hot and 
hard water connection 

approx. 19.5 gal/h 

approx. 74 l/h 

KWF 

Cold Water

(

Liquid

dispensing

)

Water pressure/Min. flow rate 

14.5 psi 

100 kPa 

Water pressure/Max. flow rate 

145.04 psi 

1000 kPa 

Max. volume flow 

1.45 gal/min 

5.5 l/min 

1 Connector hose with threaded joint 3/4” optionally 
included with the unit. 
Threaded connector fitting at site as per DIN 44991 
(flat sealing) 

3/4" external thread 

Length of connector hose 

59 1/16" 

1500 mm 

AV 

Drainage

Max. water outflow temperature 

203 °F 

95°C 

Dump valve 

Drainage supports in machine (outer diameter) 

15

/

16

"

75 mm [DN 70] 

On-site drain connection (inner diameter) 

15

/

16

"

75 mm [DN 70] 

Max. transient throughput 

52.8 gal/min 

200 l/min 

Vented drainage required. If ventilation is 
insufficient, fit Miele kit, Mat. no. 05238090. 
Drain manifolds serving several machines must be 
of sufficient cross-section. 

Fittings

Without base 

It is essential to ensure that the appliance is 
fastened adequately to the floor! 
Fastening material included with unit: 
2 x mounting brackets (from transport lock) 
2 x wood screws DIN 571 (Ø x length) 

8 mm x 80 mm 

2 x screw anchors (Ø x length) 

5/16" x 3 

1

/

8

"

1/2" x 2 3/

8

"

12 mm x 60 mm 

A sufficiently firm floor with sufficient load-bearing 
capacity is necessary for the installation. The 
fastening material included is only suitable for a 
solid concrete floor. The fastening material for other 
suitable floor types must be provided on site. 

Summary of Contents for PW 6207 D

Page 1: ...lation plan Washer PW 6207 D Steam Heated Always read operating and installation instructions before Installation and Commissioning This is for the protection of yourself and your machine en US 10 002 290 01 ...

Page 2: ...2 10 002 290 01 It is essential to read the operating and installation instructions before installing commissioning or using the machine This avoids the risk of accidents or damage All rights reserved ...

Page 3: ...10 002 290 01 3 Machine dimensions measurements in millimeters ...

Page 4: ...4 10 002 290 01 Connections measurements in millimeters ...

Page 5: ...10 002 290 01 5 Machine dimensions measurements in millimeters ...

Page 6: ...6 10 002 290 01 Machine dimensions measurements in millimeters ...

Page 7: ...10 002 290 01 7 Machine dimensions measurements in inches ...

Page 8: ...8 10 002 290 01 Connections measurements in inches ...

Page 9: ...10 002 290 01 9 Machine dimensions measurements in inches ...

Page 10: ...10 10 002 290 01 Machine dimensions measurements in inches ...

Page 11: ...d in base Height 9 7 16 240 mm Width 36 1 4 920 mm Depth 40 1 8 1019 mm BS Concrete base Quality and density of concrete must comply with load Concrete base must be firmly secured to floor Recommended height 9 7 16 240 mm Minimum height 3 15 16 100 mm Minimum width 36 1 4 920 mm Minimum depth 41 5 16 1050 mm DAV Steam connection valve The steam valve regulating the steam flow must be provided on s...

Page 12: ...mend connecting the appliance via a plug connection so that an electrical safety check can be carried out e g during repair or maintenance If it is necessary to install a residual current device RCD in accordance with the local regulations a residual current device type B AC DC sensitive must always be used PA Potential equalization Externally threaded supports for shrims and nuts If necessary equ...

Page 13: ...ld water valve KWH Cold water Water pressure Min flow rate 14 5 psi 100 kPa Hard water Water pressure Max flow rate 145 04 psi 1000 kPa Max volume flow 8 45 gal min 32 l min Threaded connector fitting at site as per DIN 44 991 flat sealing 1 external thread Length of connector hose 59 1 16 1500 mm Avarage water requirement for a standard program 60 colored washing determined at cold hot and hard w...

Page 14: ...h 8 mm x 80 mm 4 x screw anchors Ø x length 5 16 x 3 1 8 1 2 x 2 3 8 12 mm x 60 mm The installation and assembly of the appliance and base must follow the installation instructions provided Machine data Width 36 3 8 924 mm Depth 44 1 2 1130 mm Height 55 1 8 1400 mm Housing width 36 1 4 920 mm Housing depth 40 3 16 1020mm Width loading opening clear width 36 5 8 930 mm Recommended wall spacing to r...

Reviews: