6 Cleaning and maintenance
|
English
Quick guide PTD 901
|
12019630; 2021-09
|
49
Caution
Danger of rust formation in the filling area as a result of salt
residues
Ø
After filling the regeneration salt, start a washing programme or the
self-cleaning programme in order to wash away any salt residues that
may be present.
Ø
Only fill with water when commissioning the water softener for the first time.
Ø
Top up the regeneration salt.
~ 1,5 l
~ 1,5 kg
6.5
Replace canister
1
1
Ø
Wear protective clothing, protective gloves and protective goggles.
Ø
Pull the suction tube carefully out of the empty canister.
Ø
Check whether both vent holes (1) in the caps are open. Clean if re-
quired.
Ø
Place suction tube in the new canister.
Ø
Slide the cap slowly downwards until the canister opening is closed.
The dosing device must be vented if air has entered the dosing hose. This occurs if the
canister is not replaced in time.
Ø
Access the following menu (see the front fold-out page):
1
2
Item Name
1
Rinse aid dosing device
2
Detergent dosing device
Ø
Press button 1 or 2.
ð
The button turns white.
ð
The dosing device is being vented.
Ø
As soon as the button turns dark again,
exit the menu.