en - Areas of application
31
Preparing the load
Preparing the in-
sert
Place the APFD 200 insert on the worktop. The insert must be
stable.
Remove the small-part baskets and place these on the left and right
next to the APFD 200 insert.
The quick-release couplings on the insert should have the same col-
our coding as the accompanying compartments of the small-part
baskets so that you can assign the air regulator small parts clearly.
Pre-cleaning air
regulators
Check whether the air regulator requires manual pre-cleaning, e.g.
to remove soot.
If required, carry this pre-cleaning out in line with the manufac-
turer’s instructions.
Dismantling air
regulators
Dismantle the air regulator in line with the manufacturer’s instruc-
tions.
Place the small parts in a compartment in a small-part basket.
Do not position small parts in such a way that they will collect wa-
ter. For example, insert rubber covers with the curved hollow side
facing down.
Note the colour-coding for the small-part basket compartment to
place the air regulator in the same colour in the insert.