Do not connect the appliance to the

mains electricity supply by a
multi-socket unit or an extension lead.
These do not guarantee the required
safety of the appliance (e.g. danger of
overheating).

~

This rangehood must not be

installed and operated in mobile
installations (e.g. on a ship).

~

In areas which may be subject to

infestation by cockroaches or other
vermin, pay particular attention to
keeping the appliance and its
surroundings in a clean condition at all
times. Any damage which may be
caused by cockroaches or other vermin
will not be covered by the warranty.

Using at the same time as other
heating appliances that depend on
the air from the room

Warning - danger of toxic fumes

~

Great care should be taken when

using the rangehood at the same time
and in the same room or area of the
house as another heating appliance
which depends on the air in the room.
Such appliances include gas, oil, wood
or coal-fired boilers and heaters,
continuous flow or other water heaters,
gas cooktops or ovens which draw air
in from the room and duct exhaust
gases out through a chimney or
extraction ducting.
When used in extraction mode, the
appliance draws air in from the room in
which it is installed

and

from

neighbouring rooms.
If there is insufficient air, an
underpressure will occur. The heating
appliance may be starved of oxygen,
impairing combustion.

Harmful gases could be drawn out of
the chimney or extraction ducting back
into the room, with potentially fatal
consequences.

Warning and Safety instructions

6

Summary of Contents for DA 2050

Page 1: ...stallation instructions Rangehood DA 2050 To avoid the risk of accidents or damage to the appliance it is essential to read these instructions before it is installed and used for the first time M Nr 09 723 310 en AU NZ ...

Page 2: ...eaning and care 12 Housing 12 Grease filter 12 Fitting and replacing the charcoal filters 14 Changing a halogen lamp 15 Appliance dimensions 16 Safety distances between cooktop and rangehood S 16 Installation 18 Fitting the non return flap 18 Building in 18 Preparation for extraction 19 Electrical connection 20 Connection for air extraction 21 Condensate trap 22 Silencer 23 Electrical connection 2...

Page 3: ...contain materials which if handled or disposed of incorrectly could be potentially hazardous to human health and to the environment They are however essential for the correct functioning of your appliance or machine Therefore please do not dispose of your old machine or appliance with your household waste Please dispose of it at your local community waste collection recycling centre and ensure tha...

Page 4: ...ation of the appliance This appliance is not suitable for outdoor use This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience or knowledge unless they are supervised whilst using it or have been been shown how to use it by a person responsible for their safety This appliance may only be used in mobile installat...

Page 5: ... instructions given in the installation sheet and in the Cleaning and care section of this booklet Under no circumstances should any other parts of the housing be opened Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operational faults Installation maintenance and repairs may only be carried out by a Miele authorised person in...

Page 6: ...m Warning danger of toxic fumes Great care should be taken when using the rangehood at the same time and in the same room or area of the house as another heating appliance which depends on the air in the room Such appliances include gas oil wood or coal fired boilers and heaters continuous flow or other water heaters gas cooktops or ovens which draw air in from the room and duct exhaust gases out ...

Page 7: ...ver use an open flame beneath the rangehood To avoid the danger of fire do not flambé or grill over an open flame When switched on the rangehood could draw flames into the filter Fat particles drawn into the rangehood present a fire hazard When using the rangehood over a gas cooktop ensure that any burners in use are always covered by a pan Switch the cooking zone off when a pan is removed even fo...

Page 8: ...cooktop manufacturer states that a greater safety distance is required If more than one cooking appliance is fitted beneath the rangehood and they have different minimum safety distances to the rangehood select the greater distance Safety regulations prohibit the fitting of a rangehood over solid fuel stoves All ducting pipework and fittings must be of non flammable material These can be obtained ...

Page 9: ...ens for the cooking vapours to be blown directly outside Please note the performance of this rangehood hinges greatly on the installed ducting to vent the vapours Poor choice of ducting results in poor rangehood performance For ducting recommendations please refer to the relevant section in these operating instructions or contact a specialised installer air recirculation requires a conversion kit ...

Page 10: ...a Lighting switch b Fan switch c Cooktop lighting d Charcoal filters Special accessory for recirculation mode e Grease filter Guide to the appliance 10 ...

Page 11: ...e filtered Depending on the intensity of the cooking vapours levels 1 and 2 are usually sufficient for normal cooking Intensive setting For short periods of cooking food with intensive vapours and a strong aroma e g when searing meat you may wish to select the Intensive Setting IS After cooking If the air still needs to be cleared after cooking we recommend letting the rangehood continue to run fo...

Page 12: ...p liquid applied with a well wrung out soft sponge or cloth Wipe the surfaces dry using a soft cloth Do not use cleaning agents containing soda acids chlorides or solvents abrasive cleaning agents e g powder cleaners or cream cleaners and abrasive sponges as well as pot scourers or sponges which have been used previously with abrasive cleaning agents These will damage the surface material Grease f...

Page 13: ...a Miele dishwasher is being used select the Sensor wash programme Use a mild dishwasher detergent Depending on the cleaning agent used cleaning the filters in a dishwasher can cause permanent discolouration to the surface However this will not affect the functioning of the filters in any way After cleaning leave the filter to dry for a while on an absorbent surface before putting it back in place ...

Page 14: ...contact details and Technical data for the model number of the filter Before fitting or replacing the active charcoal filters the grease filter must first be taken out see previous section for instructions on how to do this Unwrap the charcoal filters Insert the charcoal filters into the canopy Replace the grease filter Replace the charcoal filters when they no longer absorb kitchen odours effecti...

Page 15: ...after being switched off Do not touch the surface directly when changing a lamp as grease particles from your fingers will adhere to the surface and damage it Please follow the manufacturer s instructions Push down the lighting unit slightly via the opening in the safety panel The halogen lamp is now accessible and should be unscrewed anti clockwise Replace it with a new halogen lamp specification...

Page 16: ...lectric cooktop 600 mm Open electric grill 650 mm Deep fat fryer electric 650 mm Multi burner gas cooktop with maximum 45 4 MJ h total output with no burner having a greater output than 16 2 MJ h 650 mm Multi burner gas cooktop with total output greater than 45 4 MJ h or a gas cooktop including a single burner with an output greater than 16 2 MJ h 760 mm Single gas cooktop with a maximum output of...

Page 17: ...more working space under the hood Account should also be taken of the height of the person who will be using the hood most often The person should have sufficient space to work comfortably at the cooktop and also be able to reach the rangehood controls with ease Please be aware that if positioned too high extraction will be inefficient Appliance dimensions 17 ...

Page 18: ...reakfast bars or island areas Check prior to installation that the top of the appliance will be accessible after installation If this is not the case install the exhaust ducting and prepare the electrical connection before installation Place the appliance in the cut out from below and align it Secure the rangehood by the frame using 3 5 x 16 mm screws Before using the appliance for the first time ...

Page 19: ...d See Connection for air extraction for further instructions on fitting the ducting Recirculation If site conditions are not suitable for the rangehood to be used with air extraction the appliance must be set up for recirculation For this conversion kit DUU 151 available from Miele Chartered Agent or Miele is required You will also need two charcoal filters see Technical data Installation 19 ...

Page 20: ...the exhaust grille make sure that the slats in the grille point towards the centre of the room and not directly towards a wall or the ceiling Fit the charcoal filters Electrical connection Before connecting the appliance read the safety notes in Warning and Safety instructions and Electrical connection Installation 20 ...

Page 21: ...g is used the noise level of the rangehood will increase and extraction will be less efficient All ducting pipework and fittings must be of non flammable materials The exhaust ducting should be as short and straight as possible Only use wide radius bends The exhaust ducting should not be kinked or compressed Ensure that all connections are strong and airtight Where ducting is horizontal it must be...

Page 22: ...installing a condensate trap to collect and evaporate any condensate which may occur Condensate traps are available for C 125 mm or C 150 mm ducting When installing a condensate trap ensure that it is positioned vertically and if possible directly above the exhaust connection The arrow on the housing indicates the direction of air flow Connection for air extraction 22 ...

Page 23: ... outside e g traffic noise For this reason the silencer must be positioned as close as possible to where the ducting leaves the building a in recirculation mode The silencer needs to be positioned between the fan and the exhaust grille b Ensure there is adequate space for fitting it In all modes of operation the most effective noise reductions are achieved if two silencers are fitted in the system...

Page 24: ...hold mains supply Connection of this appliance should be made via a suitable isolator which complies with national and local safety regulations and the On Off switch should be easily accessible after the appliance has been built in If the switch is not accessible after installation an additional means of disconnection must be provided for all poles For extra safety it is advisable to install a sui...

Page 25: ...of Miele on the back cover of the manual Please quote the model and serial number when contacting Miele These are shown on the data plate which is visible when the grease filters are removed Warranty The warranty for this appliance is 2 years For further information please refer to your warranty booklet After sales service 25 ...

Page 26: ... power according to EN 61591 Extraction system C 150 mm Level I 150 m3 h Level II 280 m3 h Level IV Intensive Setting 400 m3 h Recirculation with charcoal filters Level I 120 m3 h Level II 230 m3 h Level IV Intensive Setting 360 m3 h Special accessories for recirculation mode Conversion kit DUU 151 Miele charcoal filter pack DKF 15 1 each pack contains 2 filters Technical data 26 ...

Page 27: ...27 ...

Page 28: ...Alteration rights reserved 3013 M Nr 09 723 310 00 ...