Connection for extraction
Only use narrower diameter pipe-
work where it is unavoidable, for
example where existing pipework
has to be used. The narrower the
diamater the lower the performance
and the noiser the operation.
Extraction connection should only
be carried out in accordance with
building regulations.
Connect the vent ducting and se-
cure with a hose clip.
Proceed with the extraction connec-
tion.
Important
If the exhaust ducting is to run through
rooms, ceiling space etc. where there
may be great variations in temperature
between the different areas the prob-
lem of sweating or condensation will
need to be addressed.
The exhaust ducting will need to be
suitably insulated.
In addition to insulating the exhaust
ducting we recommend that a suitable
condensate trap is also installed to col-
lect and evaporate any condensate
which may occur.
Condensate traps are available from
the Miele Spare Parts Department.
When installing a condensate trap
ensure that it is located vertically
and if possible directly above the
exhaust connection.
Connection for air extraction