background image

Operating and Installation
Instructions

Ventilation System
DA 270

To prevent accidents
and machine damage,
read these instructions

before

installation or use.

UV

05 854 670

M.-Nr.

Summary of Contents for DA 270

Page 1: ...Operating and Installation Instructions Ventilation System DA 270 To prevent accidents and machine damage read these instructions before installation or use UV 05 854 670 M Nr ...

Page 2: ...ing off the fan 11 Delayed Shut Down 11 Turning the lighting on off 12 Dimming the lighting 12 Indirect lighting 12 Filter timers 13 Checking the filter timers 13 Reprogramming the grease filter timer 14 Cleaning and Care 15 Cleaning the casing 15 Grease filters 16 Changing the light bulb 18 After Sales Service 19 Installation instructions 21 Contents 2 ...

Page 3: ...trical safety of this appliance continuity must exist between the appliance and an effective grounding system It is imperative that this basic safety requirement be met If there is any doubt have the electrical system of the house checked by a qualified electrician The manufacturer can not be held responsible for damages caused by the lack or inadequacy of an effective grounding system Before conn...

Page 4: ...d and any doors to prevent hazards Use Do not allow children to play with or operate the appliance or its controls Supervise its use by the elderly or infirm Be careful when preparing a flambé beneath the hood Flames may be drawn up into the hood by the suction or grease filters may catch fire Never operate gas burners without pots Do not leave cooking surfaces unattended while in use Over heated ...

Page 5: ...OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN You may be burned DO NOT USE WATER including wet dishcloths or towels a violent steam explo...

Page 6: ...sion cords do not guarantee the required safety of the appliance e g danger of overheating Do not install this hood over cooktops burning solid fuel Any fittings sealant or materials used to install the ductwork must be made of approved non flammable materials Never connect an exhaust hood to an active chimney dryer vent vent flue or room ventilating ductwork Seek professional advice before connec...

Page 7: ... The hood comes equipped with a non return flap This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur When the hood is turned on the air pressure of the exhaust fan automatically opens the flap blowing the inside air and cooking odors outside Functional description 7 ...

Page 8: ...Guide to the hood 8 ...

Page 9: ...lso dims the light The lighting can be used independently from the fan i On Off button j Fan power selection k Delayed shut down This button activates the Delayed Shut Down feature The fan can be set to turn off automatically after either 5 or 15 minutes l Grease filter button The indicator next to the grease filter button lights when the grease filters need to be cleaned Guide to the hood 9 ...

Page 10: ...setting Level 4 yellow indicator should be used for a short period when frying or cooking food with a strong aroma Fan performance The maximum air flow capacity is 625 cfm Factors such as narrow duct diameter and bends will affect this value There will also be a slight decrease in airflow for hoods operated in recirculation mode due to the active charcoal filter Level 1 operates at 40 capacity Lev...

Page 11: ...he fan back on again Delayed Shut Down If odors or smoke remain in the kitchen after cooking has been completed the Delayed Shut Down feature can be selected to allow the hood to continue running for either 5 or 15 minutes Press the Delayed Shut Down button while the fan is still running Press once 5 minutes delay left indicator lights Press twice 15 minutes delay right indicator lights To cancel ...

Page 12: ...the lighting can be adjusted While the lighting is turned on press the light button The lighting will dim until the button is released If the button is pressed again the lighting will brighten until the button is released If the button is pressed continuously the light will cycle between bright and dark Press the light button again to turn off the lighting Indirect lighting Press the indirect ligh...

Page 13: ...s the grease filter button for about 3 seconds The indicator will go out Checking the filter timers To check the percentage of time already used Press the On Off button to turn the fan on Press the grease button The number of flashing _ indicators show the percentage of programmed hours that have been used 1 indicator less than 25 2 indicators less than 50 3 indicators less than 75 4 indicators le...

Page 14: ...ing more difficult Press the On Off button to turn off the fan Press the Delayed Shut Down and grease filter buttons at the same time The indicator for the grease filter and one of the _ indicators will flash The lit indicator shows the programmed time 1st indicator from the left 20 hours 2nd indicator from the left 30 hours 3rd indicator from the left 40 hours 4th indicator from the left 50 hours...

Page 15: ...d liq uid dish soap applied with a soft sponge Wipe dry using a soft cloth Do not use too much water when cleaning the controls Water could penetrate the electronics and cause damage Glass surfaces can be cleaned using glass cleaner Stainless steel Stainless steel surfaces can be cleaned using a non abrasive stainless steel cleaner To help prevent resoiling a conditioner for stainless steel can be...

Page 16: ...leaning the grease filters Clean the filters by hand use a scrub brush in warm water with a mild detergent in a dishwasher place the filters vertically in the lower basket making sure that the spray arm is not blocked Depending on the detergent clean ing the grease filters in a dishwasher may cause permanent discoloration of the filter surface Performance of the filter will not be affected by this...

Page 17: ...all screwdriver into the slit along its edge to disengage it from the casing After returning the grease filters press the grease filter button for 3 seconds to reset the timer The indicator light will go out If the grease filters are cleaned before the grease filter timer has reached its maximum press the grease filter button for 6 seconds to reset the counter to zero Cleaning and Care 17 ...

Page 18: ...bulbs until they have had sufficient time to cool down Do not touch the bulb surface Fingerprints or body oils deposited on the bulb will decrease the life of the bulb Follow the bulb manufacturer s instructions To change the halogen bulb first remove the lamp cover a Pull the bulb b out of its socket and replace with a new one Return the lamp cover a Never use the lighting without the lamp cover ...

Page 19: ...l Service Department USA 1 800 999 1360 techserv mieleusa com CDN 1 800 565 6435 service miele ca When contacting the Technical Service Department please quote the model and serial number of your appliance These are shown on the data plate which is visible when the grease filter is removed After Sales Service 19 ...

Page 20: ...20 ...

Page 21: ...Installation Instructions ...

Page 22: ...Contents Caring for the environment 23 Structural support 24 Electrical data 25 Appliance dimensions 26 Installation 27 Air extraction 32 Contents 22 ...

Page 23: ...ings bags etc are disposed of safely and kept out of the reach of children Danger of suffocation Disposal of an old appliance Old appliances may contain materials that can be recycled Please contact your local recycling authority about the possibility of recycling these materials Before discarding an old hood unplug it from the outlet and cut off its power cord to prevent hazards Caring for the en...

Page 24: ...This ceiling plate must be attached to rigid structural framing that is supported in its entirety by the ceiling joists or to the ceiling joists directly Do not attach the plate directly to the ceiling by using anchors mollies or toggle bolts Structural support 24 ...

Page 25: ...te located behind the grease filters match the household electrical supply before installing the hood If there is any question concerning the electrical connection of this appliance to your power supply please consult a licensed electrician or Miele s Technical Service USA 1 800 999 1360 CDN 1 800 565 6435 WARNING THIS APPLIANCE MUST BE GROUNDED Important The hood must be hard wired accordingly Bl...

Page 26: ...a Mounting bolt holes b Cut out for power cord c Exhaust connection 6 150 mm diameter Appliance dimensions 26 ...

Page 27: ... than one appliance beneath the hood and they have different minimum safety distances always select the greater distance Observe local building codes See Important Safety Instructions for further information 26 65 cm is recommended for all installations to allow for optimum work space under the hood CAUTION During the installation process please be careful of sharp edges that can cause harm Mark a...

Page 28: ...power cable b to reach the power terminal located at the top of the hood s chimney Feed the ductwork and power cord through their respective holes in the ceiling If 6 150 mm ductwork is not possible then 5 125 mm ductwork can be used in conjunction with a reducing collar available from Technical Service see Installation Air extraction for further details Drill four 3 16 5 mm holes in the ceiling T...

Page 29: ... from below and pivot them 90 so that the tab faces the center of the mounting brake Pull the power cord through the mounting plate Insert the four countersunk screws M 6 x 20 into the recessed holes from above Tape the screws from above to prevent them from being pushed upwards when the nuts are tightened Installation 29 ...

Page 30: ... mounting plate can safely support the weight of the hood Using at least two people lift the hood and guide the spring clips through their respective slots in the flange at the top of the chimney Make sure they click into place and that the hood is hanging securely from the spring clips before allowing them to carry the weight Installation 30 ...

Page 31: ...ec tion read the Important Safety Instructions and Electrical data sections Finally being careful not to scratch the chimney push the cover plate up until the spring fixing clips click into place If installed correctly the cover should be secure and flush against the ceiling Before using the appliance remove the grease filter and remove the protective foil from the filter frame Reseat the filter I...

Page 32: ...uctwork should not be less than 6 150 mm Use of flat ducts also reduces the air extraction efficiency Noise levels of the hood will increase if flat ducts or round ducts of less than 6 150 mm in diameter are used WARNING To reduce the risk of fire only use metal ductwork CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces withi...

Page 33: ...an exhaust hood vent to an existing inactive chimney or vent flue If the ductwork runs through rooms ceilings garages etc where temper ature variations exist it may need to be insulated to reduce condensation In some cases a condensate trap may also be required to collect and evaporate any condensate which may occur When installing a condensate trap ensure that it is positioned vertically and if p...

Page 34: ...34 ...

Page 35: ...35 ...

Page 36: ...Alteration rights reserved 0203 This paper is bleached without the use of chlorine 00 M Nr 05 854 670 V ...