background image

Operating and installation instructions 

Rangehood

To prevent the risk of accidents or damage to the appliance, it is

essential

 to read these instructions before it is installed and used for

the first time.

en - AU, NZ

M.-Nr. 09 705 600

Summary of Contents for DA 416-6

Page 1: ... installation instructions Rangehood To prevent the risk of accidents or damage to the appliance it is essential to read these instructions before it is installed and used for the first time en AU NZ M Nr 09 705 600 ...

Page 2: ...ease filters 19 NoSmell active charcoal filter 21 Disposing of the charcoal filter 21 Changing a halogen lamp 22 Installation 23 Before installation 23 Protective foil 23 Installation instructions 23 Dismantling 23 Assembly parts 24 Appliance dimensions 26 Safety distance S 27 Installation recommendations 28 Drilling diagram for wall mounting 28 Connection for air extraction 29 Condensate trap 30 ...

Page 3: ...ication This rangehood is designed for domestic use and for use in similar environments by guests in hotel or motel rooms bed breakfasts and other typical living quarters This does not include common shared facilities or commercial facilities within hotels motels or bed breakfasts The appliance is not suitable for outdoor use It must only be used to extract vapours and remove odours from cooking A...

Page 4: ...le to use it safely recognising the dangers of misuse Cleaning work may only be carried out by older children under the supervision of an adult Children should be supervised near the appliance Ensure that they do not play with the appliance Danger of suffocation Children may be able to wrap themselves in packing material or pull it over their heads with the risk of suffocation Keep children away f...

Page 5: ...ystem It is most important that this basic safety requirement is present and tested regularly and where there is any doubt the household wiring system should be inspected by a qualified electrician Before connecting the appliance to the mains supply ensure that the connection data on the data plate voltage and frequency matches the mains electricity supply This data must correspond in order to avo...

Page 6: ...ele approved service technician Faulty components must only be replaced by genuine Miele spare parts The manufacturer can only guarantee the safety of the appliance when Miele replacement parts are used If the electrical connection cable is faulty it must only be replaced by a Miele authorised service technician to protect the user from danger During installation maintenance and repair work the ap...

Page 7: ...water heaters gas cooktops or ovens which draw air in from the room and duct exhaust gases out through a chimney or extraction ducting When used in extraction mode with or without an external motor fitted or in recirculation mode with a recirculation box installed outside the room the appliance draws air in from the room in which it is installed and from neighbouring rooms If there is insufficient...

Page 8: ...s ensuring that the rangehood can only be switched on when the heating appliance is switched off or vice versa A ventilation brick alone is not generally sufficient to ensure safe ventilation The overall ventilation condition of the dwelling must be taken into account If in any doubt the advice of a competent builder or for gas a qualified gas fitter registered with an official gas safety body in ...

Page 9: ...s covered by a pan Switch the cooking zone off when a pan is removed even for a short time Select a pan which is suitable for the size of the burner Regulate the flame so that it does not burn up the sides of the pan Avoid overheating the pan e g when cooking with a wok Always switch the rangehood on when a cooking zone is in use otherwise condensation may collect in the rangehood which could caus...

Page 10: ...acturer s instructions as to whether a rangehood may be operated above the cooktop Safety regulations prohibit the fitting of a rangehood over solid fuel stoves Insufficient distance between the cooktop and the rangehood can result in damage to the rangehood The minimum safety distances between the top of the cooktop and the bottom of the rangehood given in the Installation section must be maintai...

Page 11: ...tilates rooms with fireplaces If exhaust air is to be extracted into a chimney or ventilation duct no longer used for other purposes seek professional advice Cleaning and care Do not use a steam cleaning appliance to clean this appliance The steam could reach electrical components and cause a short circuit Accessories Use only genuine original Miele spare parts If spare parts or accessories from o...

Page 12: ...fely and kept out of the reach of babies and young children Danger of suffocation Disposing of your old appliance Electrical and electronic appliances often contain materials which if handled or disposed of incorrectly could be potentially hazardous to human health and to the environment They are however essential for the correct functioning of your appliance Therefore please do not dispose of you...

Page 13: ... closed when the rangehood is switched off When the rangehood is switched on the non return flap opens for the cooking vapours to be blown directly outside If the on site ventilation system does not have a non return flap the non return flap supplied must be fitted Recirculation mode available as an optional extra with a conversion kit and charcoal filter see Technical Data The air is drawn in and...

Page 14: ...Guide to the appliance 14 ...

Page 15: ...Grease filters f Recirculation grilles only for recirculation mode g Cooktop lighting h NoSmell active charcoal filter special accessory for recirculation mode i On Off touch control for the fan j Touch controls to select the fan power setting k On Off touch control for the cooktop lighting ...

Page 16: ...tting so that it always only runs for 10 minutes before reverting automatically to setting 3 To set this option both the fan and the cooktop lighting must be switched off Press the and controls at the same time for approx 10 seconds until the 1 lights up Then press in turn the lighting control then the touch control and the lighting control again If Automatic switch off is not activated the 1and I...

Page 17: ... The cooktop lighting can be switched on and off independently of the fan To do this press The symbol will light up when the cooktop lighting is switched on Safety switch off Should the rangehood be left on the fan will switch off automatically after 10 hours The lighting will remain on Pressing the On Off control will switch the fan back on again ...

Page 18: ...r sponges which have been used previously with abrasive cleaning agents These will damage the surface material Important for appliances with stainless steel surfaces This infomation does not apply to the controls Stainless steel surfaces can be cleaned with a proprietary non abrasive cleaning agent designed specifically for use on stainless steel To help prevent re soiling a proprietary conditioni...

Page 19: ...st etc from the kitchen vapours preventing soiling of the rangehood An oversaturated filter is a fire hazard When to clean the grease filters The grease filters should be cleaned regularly at least every 3 4 weeks to avoid a build up of grease Removing the grease filters The grease filters can fall out when you are handling it This can result in damage to the filters and the cooktop below Make sur...

Page 20: ...uring the spray arm is not obstructed Use a proprietary household dishwasher detergent Select a dishwasher programme with a wash temperature between 50 C and 65 C Depending on the cleaning agent used cleaning the filters in a dishwasher can cause permanent discolouration to the surface However this will not affect the functioning of the filters in any way After cleaning After cleaning leave the fi...

Page 21: ...Fitting and replacing a charcoal filter Before fitting or replacing the charcoal filter the grease filters must first be taken out see previous section for instructions on how to do this Unwrap the charcoal filter from its packaging Insert the charcoal filter into the back of the charcoal filter frame then push up into the frame at the front Refit the grease filters When to change the NoSmell acti...

Page 22: ... electrical supply before replacing the lamps see Warning and Safety instructions To access the halogen lamp press the lamp cover gently upwards The cover will open and can then be lowered Pull the halogen lamp out of its socket Replace it with a new halogen lamp 12 V 20 W G4 Wear a glove or use a soft cloth to hold it and push it into the socket carefully Please follow the lamp manufacturer s ins...

Page 23: ...oil before fitting the housing components It can be peeled off easily Installation instructions See enclosed installation sheet for instructions on how to install this appliance Dismantling Should the appliance ever need to be dismantled follow the installation instructions in reverse order as described on the installation sheet A lever is supplied to assist with the removal of the tower After uns...

Page 24: ...Installation 24 Assembly parts ...

Page 25: ...inium hose and hose clips the conversion kit is not supplied It is available as an optional extra see Technical data 8 screws 5 x 60 mm and 8 plugs 8 x 50 mm for securing the wall bracket The screws and plugs are designed for use in solid walls only For other types of wall construction alternative fixings will be required Make sure the wall is able to take the weight of the rangehood 2 x M 6 self ...

Page 26: ...Installation 26 Appliance dimensions The drawing is not to scale ...

Page 27: ...nding on model and the bottom of the rangehood are as follows unless a greater distance is specified by the manufacturer of your cooking appliance See also Warning and Safety instructions Cooking appliance Minimum distance S Electric cooktop 600 mm Open electric grill 650 mm Deep fat fryer electric 650 mm Multi burner gas cooktop with maximum 45 4 MJ h total output with no burner having a greater ...

Page 28: ...e side The cooktop should be no wider than the rangehood and if possible it should be narrower especially for distances greater than 750 mm The installation area must be easily accessible The rangehood should be easily accessible and easy to dismantle in the event that service is required This should be taken into consideration when planning the position of cupboards shelves ceilings or features i...

Page 29: ...xtraction the diameter of the exhaust ducting should not be less than 150 mm If flat ducting is being used the cross sectional area must not be smaller than the cross sectional area of the exhaust connection The exhaust ducting should be as short and straight as possible Only use wide radius bends The exhaust ducting should not be kinked or compressed Ensure that all connections are strong and air...

Page 30: ...nsure that it is positioned vertically and if possible directly above the exhaust connection The arrow on the housing indicates the direction of airflow Silencer To achieve even further reductions in noise levels a special silencer optional accessory can be fitted in the ducting system Air extraction mode The silencer not only reduces noise from the motor outside the house but also sounds from out...

Page 31: ...Connection for air extraction 31 Recirculation mode The silencer needs to be positioned between the exhaust connection and the directional unit Ensure there is adequate space in the tower for fitting it ...

Page 32: ...n carried out For extra safety it is advisable to install a residual current device RCD with a trip current of 30 mA Connection of this appliance should be made via a suitable isolator which complies with national and local safety regulations and the On Off switch should be easily accessible after the appliance has been built in If the mains socket is not accessible after installation an additiona...

Page 33: ... back of these instructions When contacting Miele please quote the model and serial number of your appliance These can be found on the data plate Position of the data plate The data plate is visible after removing the grease filters Warranty The manufacturer s warranty for this appliance is 2 years For further information please refer to your warranty booklet ...

Page 34: ...length 1 5 m Weight DA 416 6 21 kg DA 419 6 25 kg Extraction power according to EN 61591 extraction ducting 125 150 mm Setting 1 130 150 m h Setting 2 230 250 m h Setting 3 330 350 m h Intensive setting 450 500 m h Recirculation power Setting 1 100 m h Setting 2 150 m h Setting 3 250 m h Intensive setting 350 m h Recirculation mode with conversion kit DUW 20 and charcoal filter DKF 12 optional acc...

Page 35: ...Z WY 6f gVUbY ARVEY 3TREET ORTH AGLE ARM 1 A Y Y 7YbhYf UbX CZZ WY 5XY U XY 3IR ONALD RADMAN RIVE ILTON 3 3TIRLING IGHWAY LAREMONT 7 A Y Y 7YbhYf UbX CZZ WY DYfh 0LHOH XVWUDOLD 3W WG 0LHOH 1HZ HDODQG LPLWHG 5NIT 3YLVIA 0ARK 2OAD T 7ELLINGTON UCKLAND A Y Y 7YbhYf 5iW_ UbX OLLEGE ILL REEMANS AY UCKLAND 4ELEPHONE WWW MIELE CO NZ 0LHOH OREDO HDGTXDUWHUV HUPDQ 0LHOH LH ARL IELE 3TRA E àTERSLOH EDERAL 2...

Page 36: ...M Nr 09 705 600 00 en AU NZ DA 416 6 DA 419 6 ...

Reviews: