Electrical connection if using an
external blower
If using the external blower, install a
connection cable between the
ventilation system and the external
blower.
Please follow the Operating and
Installation Instructions for the
DAG 1000.
^
Additional housing knock-outs should
be used for the external blower
housing.
^
Install a suitable UL listed cable
clamp or conduit fitting into the
knock-out.
^
Connect to the power supply as
described previously.
^
The external blower will be
connected to the additional control
cable.
^
Close the terminal box.
^
Turn the power supply back on.
Maximum load
with interior-mounted
DAG 500 vent motor . . . . . . . . . . 420 W
with exterior-mounted
DAG 1000 vent motor . . . . . . . . . 210 W
Voltage . . . . . . . . . . . . . . . . . . . . . 120 V
Frequency . . . . . . . . . . . . . . . . . . 60 Hz
Circuit Rating . . . . . . . . . . . . . . . . . 15 A
Electrical connection
38
Summary of Contents for DAG 1000
Page 8: ...Description of the appliance 8 ...
Page 16: ...16 ...
Page 18: ...18 ...
Page 20: ...Appliance dimensions 20 ...
Page 22: ...Cabinet dimensions Appliance dimensions 22 ...
Page 39: ...39 ...