Installation
-
I
N
-
S
T
A
L
L
-
A
-
T
I
O
N
-
107
Electrical connection
We recommend that you connect the
steam oven to the power supply using a
suitable switched electrical socket. This
makes it easier to perform servicing
work. The socket must be easily ac-
cessible after the steam oven has been
installed.
Risk of damage from incorrect
connection.
Installation, repairs and other main-
tenance work by unqualified persons
could be dangerous. Miele cannot be
held liable for unauthorised work.
Miele cannot be held liable for dam-
age or injury caused by the lack of or
inadequacy of an on-site earthing
system (e.g. electric shock).
If the plug is removed from the con-
nection cable or if the cable is sup-
plied without a plug, the steam oven
must be connected to the electrical
supply by a suitably qualified electri-
cian.
If the socket is no longer accessible,
or if a hard-wired connection is in-
stalled, an additional means of dis-
connection must be provided for all
poles. A suitable means of discon-
nection would include switches with
an all-pole contact gap of at least
3 mm. These include circuit break-
ers, fuses and contactors. The re-
quired connection data is provided
on the data plate. Please ensure that
these details match the electrical
supply.
After installation, ensure that all elec-
trical components are shielded and
cannot be accessed by users.
Total power rating
See data plate
Connection data
The connection data is quoted on the
data plate. Please ensure these match
the household mains supply.
Residual current device
For extra safety, it is advisable to pro-
tect the steam oven with a suitable re-
sidual current device (RCD) with a trip
range of 30 mA.
Replacing the mains connection
cable
When replacing the mains connection
cable, please use cable type H 05 VV-F
with a suitable cross-section. These
cables are available from the manufac-
turer or from Miele Service.