Technical Information
40
DGC 6xxx
Figure 030-15:
Heat-Flow Temperature Sensor Housing
11. Remove the seal from the temperature sensor, and release the
temperature sensor from its housing.
12. Disconnect the green-and-yellow ground wire from the temperature
sensor, and then disconnect the red-and-white wiring harness from the
power electronic.
Note:
The seal will be damaged during removal and must be replaced.
13. Install a
new
seal; see Figure 030-16, Item 1.
Note:
When installing the temperature sensor, always press against the seal;
otherwise, the seal will be damaged.
14. Install the temperature sensor; see Figure 030-16, Item 2.
Summary of Contents for DGC 6 Series
Page 1: ...TECHNICAL INFORMATION DGC 6xxx Combi Steam Ovens 2018 Miele USA ...
Page 15: ...Technical Information 15 DGC 6xxx 010 Casing ...
Page 23: ...Technical Information 23 DGC 6xxx 020 Door ...
Page 27: ...Technical Information 27 DGC 6xxx 030 Cavity ...
Page 43: ...Technical Information 43 DGC 6xxx 035 Steam Generator Convection Fan ...
Page 57: ...Technical Information 57 DGC 6xxx Figure 035 14 Terminal Block ...
Page 58: ...Technical Information 58 DGC 6xxx 040 Water Container Drive ...
Page 68: ...Technical Information 68 DGC 6xxx 045 Air Duct Power Electronic ...