Technical Information
60
DGC 6xxx
2.2 Water
Tank
2.2.1
Water Tank
The capacity of the water tank is 1.25 liters (40 fluid ounces).
The water tank uses two reed switches on the back of the water container.
Reed switch B3-18 registers the water level. Reed switch B3-17 detects the
presence of the water tank.
2.2.2 Water-Tank
Filling
The two float switches at the side of the water tank have their starting points
set at different levels. The higher float switch registers the presence of the
water tank, and will switch reed switch B3-17. The float switch whose starting
point is on the base of the water tank shows the current water level in the
tank, and will switch reed switch B3-18.
3
Fault Repair
3.1
Fascia Panel Does Not Open
Symptom:
The fascia panel does not open when its sensor is activated. The fascia panel
only opens after its sensor has been activated at least twice.
Cause:
The appliance is in standby mode.
Remedy:
Activate the sensor for a longer time. The standby mode is quit and the fascia
opens.
3.2
Fascia Panel Does Not Open or Close Correctly
Symptom:
The fascia panel does not open or close correctly. After the sensor is
activated again, the fascia panel opens or closes fully. It then functions
correctly.
Cause:
Initial connection of the appliance, voltage failure or manual operation of the
fascia panel.
If one of these factors has occurred, the electronic's software cannot have
registered the position of the fascia panel. This can cause the fascia panel to
not open or close fully.
Remedy:
Advise the customer accordingly.
Summary of Contents for DGC 6 Series
Page 1: ...TECHNICAL INFORMATION DGC 6xxx Combi Steam Ovens 2018 Miele USA ...
Page 15: ...Technical Information 15 DGC 6xxx 010 Casing ...
Page 23: ...Technical Information 23 DGC 6xxx 020 Door ...
Page 27: ...Technical Information 27 DGC 6xxx 030 Cavity ...
Page 43: ...Technical Information 43 DGC 6xxx 035 Steam Generator Convection Fan ...
Page 57: ...Technical Information 57 DGC 6xxx Figure 035 14 Terminal Block ...
Page 58: ...Technical Information 58 DGC 6xxx 040 Water Container Drive ...
Page 68: ...Technical Information 68 DGC 6xxx 045 Air Duct Power Electronic ...