All plumbing work should be carried
out by a suitably qualified and
competent person, in accordance
with all applicable local and national
regulations.
The water quality must conform to
country requirements for drinking
water.
– The appliance is only suitable for
connection to the cold water supply.
– The water pressure must be between
25 and 120 psi (1.72-8.25 bar).
– A separate shut-off valve must be
installed, so that the water supply
can be interrupted as needed.
– The maximum outer diameter of the
water pipe (without fittings):
3
/
8
" (10 mm).
The shut-off valve for the water
connection must not be located
behind the appliance. It is
recommended to place the shut-off
valve directly next to the appliance
(base unit) or in another easily
accessible location.
Plumbing
62
Summary of Contents for F 1411 Vi
Page 42: ...42 ...
Page 49: ...Niche dimensions A B F 1411 SF 18 469 8 mm 18 457 mm Dimensions 49 ...
Page 69: ...69 ...
Page 70: ...70 ...
Page 71: ...71 ...