background image

Fully Integrated 36” Freezer

F 1913 Vi / F 1903 Vi

F 1913 Vi / F 1903 Vi

Page 4 of 6

HINGING DETAILS

0-

1/

8"

Fr

ont

 Pa

ne

l

1"

1-

1/

4"

1-

1/

2"

0-

3/

4"

0-

3/

4"

1-

1/

4"

1-

1/

2"

1-

3/

4"

2"

1"

Cabinet Front

0-

3/

4"

1"

1-

1/

4"

1-

1/

2"

0-

1/

8"

Fro

ntP

ane

l

0-

3/

4"

1-

1/

4"

1-

1/

2"

1-

3/

4"

1"

Cabinet Front

r

o

o

D

 

°

5

1

1

r

o

o

D

 

°

0

9

s

n

o

it

p

o

 

s

s

e

n

k

ci

h

T

s

n

o

it

p

o

 

s

s

e

n

k

ci

h

T

Door Swing

32 

11

/16"

7/16"

Door Swing

14 3/8"

MAX

NOTE

: Additional space needed depending on the thickness

of front panels and handle used.

Freezer units cannot be stop pinned at 90°

NOTE

: Additional space needed depending on the thickness

of front panels and handle used.

Freezer units cannot be stop pinned at 90°

Summary of Contents for F 1903 Vi

Page 1: ...Fully Integrated 36 Freezer F 1913 Vi F 1903 Vi 8mieleusa com ...

Page 2: ...d plug power supply connects lower left rear Standard NEMA 5 15 Duplex Outlet locate less than 9 above finished floor 1 4 flexible water line tape to floor E O W All Installations must be done in accordance with local codes Sides of adjoining cabinets should be filled flush to frame to insure proper fit and finish Location Codes For Proud Installation please adjust accordingly Depth assumes a 3 4 ...

Page 3: ... panel weight 105 8 Pounds Miele Fully Integrated Freezer TKH HOC Panel Height These units do not come equipped with a front panel They are designed to accept a custom door panel supplied by the cabinet maker Miele has a unique panel integration system which allows the panels to align with the surrounding cabinets Panel size is determined in the following manner Panel Notes If the adjoining cabine...

Page 4: ...1 1 4 1 1 2 1 3 4 1 Cabinet Front r o o D 5 1 1 r o o D 0 9 s n o i t p o s s e n k c i h T s n o i t p o s s e n k c i h T Door Swing 32 11 16 7 16 Door Swing 14 3 8 MAX NOTE Additional space needed depending on the thickness of front panels and handle used Freezer units cannot be stop pinned at 90 NOTE Additional space needed depending on the thickness of front panels and handle used Freezer uni...

Page 5: ...e 5 of 6 HINGING DETAILS 0 3 4 1 1 1 4 1 1 2 0 1 8 F r o n t P a n e l 0 3 4 1 1 4 1 1 2 1 3 4 1 Cabinet Front r o o D 5 1 1 s n o i t p o s s e n k c i h T Door Swing 16 7 8 MAX 3 76 2mm 13 4 44 5mm 13 8 35mm 11 6 29 6mm 1 4 6 4mm 17 24 18mm 21 24 52mm 21 3 59mm 25 8 67mm ...

Page 6: ... n k c i h T s n o i t p o s s e n k c i h T Door Swing 38 11 16 7 16 Door Sw 16 7 MAX 7 16 11 mm 13 16 30mm 17 16 36 5mm 111 16 43mm 115 16 49 2mm Handle or object that is NOT flush with Cabinet Front When installing hing side next to an appliance or object that is within range of the door panel limit the door opening angle to 90O This is done by installing the banking pin as illustrated Insert t...