Installation
*INSTALLATION*
16
Location
This appliance should be installed in a
dry, well-ventilated room.
When deciding where to install your
refrigeration appliance, please bear in
mind that it will use more energy if
installed near to a heater, a cooker or
other appliance that gives off heat.
Direct sunlight should also be avoided.
The higher the room temperature, the
longer the compressor runs and the
higher the energy consumption of the
refrigeration appliance is.
When installing the refrigeration
appliance, please note the following:
- The socket must be easily accessible
in an emergency, not concealed
behind the appliance.
- The plug and power cable must not
touch the rear of the refrigeration
appliance as they could be damaged
by vibrations from the appliance.
- Do not plug in other appliances
behind the refrigeration appliance.
If installation near a heat source is
unavoidable, observe the following
minimum distances between the
appliance and the heat source:
- At least 3 cm
to electric or gas stoves
- At least 30 cm
to oil or coal-based stoves
If it is not possible to observe these
minimum distances, an isolation plate
must be installed between the
refrigeration appliance and the heat
source.
Climate range
The appliance is designed for use within
a certain climate range (ambient
temperatures) and should not be used
outside this range. The climate range of
the appliance is stated on the data plate
inside the appliance.
Climate range
Ambient room
temperature
SN
+10 to +32 °C
N
+16 to +32 °C
ST
+16 to +38 °C
T
+16 to +43 °C
Operating in a room which is too cold
will cause the compressor to switch off
for too long, causing the internal
temperature in the appliance to rise with
the risk of food deteriorating and going
off.