Installation
*INSTALLATION*
20
. . . without partition wall
If the refrigeration appliances are to be
installed next to each other without a
partition wall between them, they will
need to be joined together with the
side-by-side installation kit. In addition,
you must install the side panel heater to
prevent condensation from forming and
any resulting damage.
Specifications for the mains
water connection
- Connection to the water supply must
comply with the applicable
regulations in the country where the
appliance is being installed.
All appliances and systems used to
supply water to the refrigeration
appliance must also comply with the
applicable regulations in the
respective country.
- The appliance may only be
connected to the mains water supply
by suitably qualified persons.
- The quality of the incoming water
must conform to the requirements for
drinking water in the country where
the refrigeration appliance is being
used.
- Connect the stainless steel hose of
the refrigeration appliance to the
fresh water supply and do not
connect to a water supply in which
the water might stagnate.
- The refrigeration appliance is only
suitable for connection to a cold
water line.
- The water pressure must be between
200 kPa and 800 kPa (2 and 8 bar).
- A stopcock must be provided
between the stainless steel hose and
the mains water supply to ensure that
the water supply can be cut off if
necessary.
- Make sure that the stopcock is still
accessible after the refrigeration
appliance has been installed.
Summary of Contents for F 2411 Vi
Page 22: ...Installation INSTALLATION 22 30 mm 22 mm 262 mm 102 mm 102 mm 85 mm Side view ...
Page 116: ......
Page 117: ......
Page 118: ......
Page 120: ...M Nr 11 633 570 00 en AE SA F 2411 Vi F 2801 Vi F 2811 Vi F 2901 Vi F 2911 Vi ...