Anti-tip brackets
The anti-tip brackets help keep the
appliance safely secured to the
installation niche to prevent tipping.
Two anti-tip brackets are
recommended for each appliance or
appliance combination (side-by-side).
The distance "
D
" between the anti-tip
brackets
b
is the width of the
appliance.
^
Position the anti-tip brackets
b
on
the left and right walls of the
appliance niche.
^
Mark the holes through the anti-tip
brackets
b
on the floor of the
installation niche.
^
Set the brackets aside.
Assure that there are no electrical
wires or plumbing in the area which
the screws could penetrate - risk of
injury and damage.
^
Drill pilot holes:
–
1
/
8
" (3 mm) for 5 x 60 mm wood
screws
–
1
/
16
" (2 mm) for 4 x 15 mm wood
screws.
^
Tightly secure the anti-tip brackets in
the niche.
Be certain that the screws penetrate
through the flooring and into the wall
plate a minimum of
3
/
4
" (19 mm).