All plumbing work should be carried
out by a suitably qualified and
competent person, in accordance
with all applicable local and national
regulations.
The manufacturer is not liable for
damage to property due to an
incorrect installation or water
connection.
The water quality must conform to
country requirements for drinking
water.
– The appliance is only suitable for
connection to the cold water supply.
– The water pressure must be between
25 and 120 psi (1.72-8.25 bar).
– A separate shut-off valve must be
installed, so that the water supply
can be interrupted as needed.
– The maximum outer diameter of the
water pipe (without fittings):
3
/
8
" (10 mm).
The shut-off valve for the water
connection must not be located
behind the appliance. It is
recommended to place the shut-off
valve directly next to the appliance
(base unit) or in another easily
accessible location.
Plumbing
67