Installation
52
Installing the appliance in
existing kitchen units
Risk of fire and damage due to
insufficient ventilation!
If the appliance is not ventilated
sufficiently, the compressor will run
more frequently and for longer
periods. This will result in increased
energy consumption and a higher
operating temperature of the
compressor. This, in turn, can result
in damage to the compressor.
Please ensure that there is adequate
ventilation around the appliance.
It is essential to observe the required
ventilation gaps. The ventilation gaps
must not be covered or blocked in
any way.
a
Top box
b
Appliance
c
Housing unit
d
Wall
x: The appliance depth is increased by
approx. 35 mm for appliances with
wall spacers fitted.
The appliance can be built into a run of
kitchen units and installed directly next
to a kitchen furniture unit. The front of
the appliance then protrudes 65 mm
(approx. 100 mm if wall spacers are
fitted) from the front of the adjacent
furniture unit.