Ventilation

Risk of fire and damage due to

insufficient ventilation!
If the refrigeration appliance is not
ventilated sufficiently, the
compressor will run more frequently
and for longer periods. This will
result in increased energy
consumption and a higher operating
temperature of the compressor. This,
in turn, can result in damage to the
compressor.
Please ensure that there is adequate
ventilation around the refrigeration
appliance.
It is essential to observe the required
ventilation gaps. The ventilation gaps
must not be covered or blocked in
any way.

Air at the back of the appliance gets
warm.

Fitting the supplied wall spacers

The wall spacers supplied must be
used in order to achieve the stated
energy consumption values and to
prevent the build-up of condensation
at high ambient temperatures.
Appliance depth is increased by
approx. 35 mm with the wall spacers
fitted. If the wall spacers are not used,
the functionality of the appliance is not
affected. However, energy
consumption is slightly increased with
less distance between the appliance
and the wall.

Fit the wall spacers onto the back of
the appliance on the top left and
right.

Installation

Two people are required for

installing the appliance.

The appliance must be empty

when it is installed.

Move the appliance carefully on

floors that are sensitive to scratching
to prevent damage.

Summary of Contents for FN 28262

Page 1: ...to one another However your appliance can be part of a side by side installation because it is equipped with built in heating units in the side panels Please contact Miele for information on which combinations are suitable for your appliance Location This appliance should be installed in a dry well ventilated room When deciding where to install your appliance please bear in mind that it will use m...

Page 2: ...aps are adhered to and that the appliance has been installed in accordance with these installation instructions Climate range This refrigeration appliance is designed for use within specific ambient temperatures climate range Do not use in ambient temperatures for which it is not designed A lower room temperature leads to the compressor switching off for longer periods This can cause the internal ...

Page 3: ... Air at the back of the appliance gets warm Fitting the supplied wall spacers The wall spacers supplied must be used in order to achieve the stated energy consumption values and to prevent the build up of condensation at high ambient temperatures Appliance depth is increased by approx 35 mm with the wall spacers fitted If the wall spacers are not used the functionality of the appliance is not affe...

Page 4: ... If the additional adjustable foot on the lower hinge plate is not sitting correctly on the floor the appliance door may swing open or the refrigeration appliance may tip over Ensure that you unscrew the adjustable foot with the supplied spanner until it sits on the floor Then unscrew it by a further quarter turn Installing the appliance in existing kitchen units Risk of fire and damage due to ins...

Page 5: ... the doors to be opened and shut without being obstructed To match the height of the kitchen units in the run the appliance can be fitted with a suitable top box When installed next to a wall a distance of at least 45 mm must be maintained on the hinge side between the wall and the appliance The larger the ventilation gaps the more economically the compressor will work A ventilation gap of at leas...

Page 6: ...11210610 01 Installation INSTALLATION Appliance dimensions x Dimensions without wall spacers fitted Appliance depth is increased by 35 mm with the wall spacers supplied fitted ...

Page 7: ...the groove the door will not close properly and cooling performance will be reduced Condensate will build up in the interior and this can cause a build up of ice Do not damage the door seals and ensure that they do not come out of their groove Preparing to change the door hinging To change the door hinging you will need the following tools Place a suitable cover on the floor in front of the applia...

Page 8: ...t of the appliance door Remove the stopper from the top of the door and refit it on the opposite side Remove the covers from the handle then unscrew the handle and refit all these parts on the opposite side of the door Take care when refitting the covers that they click into position correctly Refit the stoppers on the opposite side To change over the spring clamp press down on the catch and pull ...

Page 9: ...ting hole in the hinge plate and then tighten the screw Insert the stopper into the other hole Remove the cover Remove the screw and screw it into the outside hole on the opposite side Turn the cover 180 and refit it in the holes on the opposite side Screw the hinge plate securely into position on the new hinge side with the screws Reinsert the hinge pin complete with washer and adjustable foot Im...

Page 10: ...n the opposite side and secure it in place with the screws If necessary drill pilot holes for the screws or use a battery operated screwdriver Replace the covers and on the opposite side Align the door with the appliance housing using the slots in the lower hinge plate Then tighten the screws ...

Page 11: ...ust be at least 10 A This appliance must be connected to a suitable switched socket The electrical installation must be in compliance with current local and national safety regulations The socket must not be concealed behind the appliance and must be easily accessible so that the appliance can be quickly disconnected from the electricity supply in case of an emergency If the socket is no longer ac...

Page 12: ...d alone inverter such as those used with an autonomous energy source e g solar power When the appliance is switched on power surges could result in a safety switch off This could damage the electronics The appliance must not be used with so called energy saving devices either These reduce the amount of energy supplied to the appliance causing it to overheat If the mains cable needs to be replaced ...

Reviews: