On furniture with door fittings (e.g.
bumps, seals, etc.)
the dimension of
these must be taken into account when
making sure there is a gap all round of
42 mm
.
^
Pull the appliance forwards by the
dimension of the door fitting to keep
the gap at 42 mm all round.
The hinges will now protrude by the
dimension of the door fitting.
Tip: Remove the door fittings! This will
ensure that the door is flush with the
surrounding kitchen unit furniture doors.
If the all round gap of 42 mm is not
maintained between the appliance
casing and the front edge of the
housing unit side wall the door may
not shut properly.
This could lead to a build-up of ice
and condensation and also cause
operational faults.
^
Align the appliance on both sides by
altering the adjustable feet using the
spanner supplied
c
.
Securing the appliance in the
niche
^
Press the appliance against the wall
on the hinge side.
^
To fix the appliance to the housing
unit at the top and bottom, screw the
long 4 x 20 mm chip board screws
a
into the hinge at the top and bottom.
Building in the appliance
43