Drainage
^
The drainage system is fitted with a
non-return valve which prevents dirty
water from flowing back into the ma-
chine via the drain hose.
^
The machine should preferably be
connected to a separate drainage
system on-site.
If separate drainage is not available
contact your Miele application spe-
cialist for professional advice.
The on-site drain connection point
should be sited between 0.3 m and 1
m above the lower edge of the ma-
chine.
If it is lower than 0.3 m lay the hose in
a curve at a height of at least 0.3 m.
The drainage system must be able to
take a minimum drainage flow of 16
l/min.
^
The inlet hose is approx. 1.4 m long,
is flexible and has an internal diame-
ter of 22 mm. It must not be short-
ened.
Hose clips are supplied for securing
it in position.
^
A longer drain hose (up to 4 m long)
is available to order from the Miele
Spare Parts Dept.
^
The drainage system must not ex-
ceed 4 metres.
See also the installation diagram sup-
plied.
Plumbing
59