Electrical connection
Electrical connections should be
made by a qualified electrician in
accordance with local and national
codes and ordinances.
Note to the installer:
Please leave these instructions with
the consumer.
Power supply
The oven is equipped with a 4 wire cord
ready for connection to a dedicated
120/240 V, 60 Hz, single phase, 3 pole -
4 wire grounding power supply.
Caution:
Disconnect the oven from the main
power supply before servicing. To re-
duce the risk of electric shock, make
sure that the appliance is properly
grounded after installation.
The supplied power cord should be
connected to a dedicated 4 wire, 30 A
circuit in the following manner:
Black wire
: connect to L1 (hot)
Red wire
:
connect to L2 (hot)
White wire
: connect to N (neutral)
Green wire
: connect to GND (ground)
If a 4 wire line is not available, a 3 wire
line may be used if the oven ground
(green) and neutral (white) are both
connected to a grounded circuit con-
ductor.
Connection details are given on the
diagram located on the top of the oven.
48