Novotronic Models
Technical Information
59
6.2.6
Fault Code F13
Cause:
The door-locking device (Pyrolitic) does not close because its drive is
defective
Remedy:
Replace locking device
Cause:
The door-locking device (Pyrolitic) does not close because the door cable
is defective
Remedy:
Replace the door lock cable
Cause:
The door-locking device (Pyrolitic) does not close because the door
temperature regulator is defective
Remedy:
Replace the door temperature regulator
6.2.7
Fault Code F14
Cause:
The door-locking device (Pyrolitic) does not close because its drive is
defective
Remedy:
Perform door lock manual override
Replace locking device
Cause:
The door-locking device (Pyrolitic) does not close because the door cable
is defective
Remedy:
Perform door lock manual override
Replace the door lock cable