Fault Code F14 (Continued)
Cause:
The door-locking device (Pyrolitic) does not close because the door
temperature regulator is defective
Remedy:
Perform door lock manual override
Replace the door temperature regulator
6.2.8
Fault Code F15
Cause:
The correct pyrolitic temperature has not been reached after 120 minutes
because the level of soiling is too high or food was left in the oven
Remedy:
Clean the oven or remove food from it
Cause:
The correct pyrolitic temperature has not been reached after 120 minutes
because the grill heater element is defective
Remedy:
Replace the roof/grill heater element
Cause:
The correct pyrolitic temperature has not been reached after 120 minutes
because the convection heater element is defective
Remedy
Replace the convection heating element
Cause:
The correct pyrolitic temperature has not been reached after 120 minutes
because the catalyser is defective
Remedy:
Replace the catalyser
Cause:
The correct pyrolitic temperature has not been reached after 120 minutes
because the catalyser Pt 1000 sensor is defective
Remedy:
Replace the catalyser Pt 1000 sensor