All electrical work should be
undertaken by a suitably qualified
and competent person in strict
accordance with national and local
safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer
cannot be held responsible for
unauthorised work.
Ensure power is not supplied to the
appliance while installation or repair
work is being carried out.
The
voltage, rated load and fusing
are
given on the data plate, visible with the
oven door open. Ensure that these
match the household mains supply.
Please quote these data, and the model
and serial number when contacting the
Miele Service dept.
Connection of this appliance should be
made either via a fused connection unit
(rated load under 3000 W), or via a
suitable isolator (rated load over 3000
W), which complies with national and
local safety regulations, and the on/off
switch should be easily accessible after
the appliance has been built in.
If the socket is not accessible after
installation (depending on country) an
additional means of disconnection must
be provided for all poles.
For extra safety it is advisable to install
a residual current device with a trip
current of 30 mA (in accordance with
DIN VDE 0664, VDE 0100 Section 739).
When switched off there must be an
all-pole contact gap of 3 mm in the
isolator switch (including switch, fuses
and relays acc. to EN 60 335).
Important U.K.
The appliance is supplied with a 3-core
cable, for connection to a single phase
230-240 V 50 Hz supply.
The wires are coloured in accordance
with the following code:
Green/yellow
= earth
Blue
= neutral
Brown
= live
In other countries check these details
with your supplier.
WARNING
THIS APPLIANCE MUST BE
EARTHED
Electrical connection UK, IRL, ZA