Technical Information
36
H 408x BM
Figure 012-10:
Magnetron Removal
Note:
When re-installing the magnetron, tighten the four locknuts securely to ensure
a good ground connection. Also re-install the ducting that was removed and
secure it in place.
Danger!
After installation is completed, as a matter of standard practice, check the
oven for a tight seal with a microwave leak detector, paying particular attention
to the door and the housing edges.
4.10
Removing High-Voltage Capacitor A4
1. Remove the appliance from its cabinet; see Section 011-4.3.
2. Remove the screws securing the appliance lid. Remove the lid.
Danger!
Before performing any service or repair work, discharge the high-voltage
capacitor. See Section A-2.
3. Remove the capacitor retaining screw.
4. Remove the capacitor from the clasp assembly.
5. Disconnect the capacitor connections.
6. Pull the foil cover off the capacitor.
Danger!
Replace the foil cover between the side wall and capacitor when installing the
high-voltage capacitor.