Technical Information
67
H 408x BM
Cause:
Power electronic (1N1) defective.
Remedy:
Replace power electronic.
3.5
F54 – Short Circuit, Roast Probe
Cause:
Temperature sensor 2R30 short-circuited.
Remedy:
1. Check connectors.
2. Replace connectors as necessary.
3. Check the roast probe temperature sensor in the service mode; see
Section 040-4.3.
4. Replace the roast probe temperature sensor as necessary.
3.6
F55 – Safety Cutoff
Symptom:
After 6 hours or 12 hours, depending on operating mode, the appliance
switches off automatically.
Cause:
The appliance was not switched off.
Remedy:
No action necessary; the appliance is in working order.
3.7
F60 – Temperature of Power Electronic Too High
Symptom:
The temperature of the power electronic (1N1) is too high.
Cause:
Insufficient ducting.
Remedy:
1. Check the ducting; refer to Section 012-2.1.
2. Check the cooling fan connectors; replace as necessary.
3. Check the cooling fan in service mode; see Section 040-4.3.
4. Replace the cooling fan as necessary.
3.8 Incorrect
Language
Was
Set
Cause:
Different languages can be programmed.
Remedy:
Use the icon as a guide to program the desired language.
3.9
Time Display in 24-Hour Format/12-Hour Format
Cause:
The time format can be programmed.
Remedy:
See Section 040-4.1.
Summary of Contents for H 4080 BM
Page 1: ...TECHNICAL INFORMATION H 408x BM Speed Ovens 2013 Miele USA ...
Page 15: ...Technical Information 15 H 408x BM 011 Casing Door Lock ...
Page 25: ...Technical Information 25 H 408x BM 012 Air Duct Magnetron ...
Page 43: ...Technical Information 43 H 408x BM 020 Door ...
Page 47: ...Technical Information 47 H 408x BM 031 Oven Cavity Wave Distribution ...
Page 52: ...Technical Information 52 H 408x BM 032 Convection Fan Heaters ...
Page 58: ...Technical Information 58 H 408x BM 040 Control Panel Electrical System ...