Technical Information
77
H 408x BM
Service Function
Option
SENSOR TEST...
DOOR SWITCH
Closed
Open
ROAST PROBE
Displays temperature.
TEMP. INTERIOR
Displays temperature.
BUTTON TEST
Button test.
RUNNING TIME...
Displays hours as 0000h.
Table 040-6:
Service Mode (H 4080 BM)
Go back:
Touch the
Clear
pad. The display reverts to the previous menu.
Quit:
Touch the
On/Off
pad.
4.4
Service Mode Overview (H 4082/4/6/8 BM)
Initial requirements:
Switch the appliance off.
Accessing:
Note:
Complete the access procedure within 10 seconds.
1. Touch and hold the
Timer
pad.
2. Touch the
On/Off
pad.
3. Release the
Timer
pad.
4. Touch the
Timer
pad 3 times and on the 3rd time
hold it
until the service
mode appears.
Acknowledgement indicator:
The display shows the following items of
SERVICE
:
INDEX...
FAULT INDEX...
FUNCTION TEST...
SENSOR TEST...
RUNNING TIME...
Options:
Touch the pad next to the desired function (refer to Table 040-7).
Service Function
Option
INDEX...
CONTROL EPX792
e.g., ID000936
POWER EPL792
e.g., ID000002
FAULT INDEX...
No faults
--
Fault registered
Fault 01, Fault 02...
Clear faults
Summary of Contents for H 4080 BM
Page 1: ...TECHNICAL INFORMATION H 408x BM Speed Ovens 2013 Miele USA ...
Page 15: ...Technical Information 15 H 408x BM 011 Casing Door Lock ...
Page 25: ...Technical Information 25 H 408x BM 012 Air Duct Magnetron ...
Page 43: ...Technical Information 43 H 408x BM 020 Door ...
Page 47: ...Technical Information 47 H 408x BM 031 Oven Cavity Wave Distribution ...
Page 52: ...Technical Information 52 H 408x BM 032 Convection Fan Heaters ...
Page 58: ...Technical Information 58 H 408x BM 040 Control Panel Electrical System ...