Guide to the machine
Pushbutton controls
Button "I" On
After pressing in button "I" the in-operation in-
dicator light "I" and the temperature indicator
light "°C" come on.
- The heater plate heats up -
Once the required temperature is reached the
temperature indicator light "°C" goes out.
When the "I" button is pressed again the
heater plate will move into position and the
roller starts.
Button "O" Off
This button is used to switch the machine off
and withdraw the heater plate.
Button "
Ö
" Reverse run
Reversing is only used to change the roller
covering or replace the padding. First switch
off the machine, the heater plate will then with-
draw. Now press the "
Ö
" Reverse run but-
ton
- the roller will only run in reverse as long as
this button is pushed in.
The indicator lights
In operation indicator light "I"
The in operation indicator light "I" comes on
when the "I" button is pressed in.
Temperature indicator light "°C"
The temperature indicator light comes on
while the machine is heating up, and it goes
out once the required temperature has been
reached.
Gas heated rotary ironers
Indicator light "
yx
" ignition fault
(and faults in the exhaust ducting)
This lights up if there is an ignition fault, or if
there is insufficient under-pressure in the ex-
haust system (exhaust ducting blocked).
Re-set switch "
yx
"(on the inside of the right
hand column, below the feed-in table)
When an ignition fault occurs, the re-set
switch can be activated after waiting for at
least one minute. If an ignition fault occurs
frequently call the Service department.
M.-Nr. 05372840