Electrical connection
63
The appliance is supplied with a mains
cable and moulded plug ready for
connection to an AC single phase 220 –
240 V 50 Hz supply.
The fuse rating must be at least 10 A.
The voltage and frequency are given on
the data plate. Please ensure that these
match the household mains supply.
Connection should be made via a
suitable switched socket which is easily
accessible. For extra safety it is
advisable to install a suitable residual
current device (RCD).
The accessibility of the plug must
always be ensured in order to be able to
quickly separate the appliance from the
mains.
If the mains socket is not accessible
after the appliance has been built in, a
separator for each terminal must be
present. There must be an all-pole
contact gap of 3 mm in the switch.
The plug and mains connection cable
must not come into contact with the
back of the appliance as vibrations can
cause damage to these components.
This, in turn, could result in a short
circuit.
Nor should other appliances be
plugged into a socket located directly
behind this appliance.
Do not connect the appliance to the
mains electricity supply by an extension
lead. Extension leads do not guarantee
the required safety of the appliance
(e.g. danger of overheating).
Do not connect the appliance to an
inverter such as those used with an
autonomous energy source e.g.
solar
power
. When switched on, peak loads
in the system can cause the safety
switch-off mechanism to be triggered.
This can damage the electronic unit.
The appliance must not be used with
so-called
energy-saving devices
either. These reduce the amount of
energy supplied to the appliance,
causing it to overheat.
If the mains connection cable needs to
be replaced, this must be done by a
qualified electrician.
WARNING:
THIS APPLIANCE MUST BE
EARTHED.