Installation
-
I
N
-
S
T
A
L
L
-
A
-
T
I
O
N
-
71
Top box
Refrigeration appliance
Housing unit
Wall
* The appliance depth is increased by
approx. 35 mm for refrigeration appli-
ances with wall spacers fitted.
The refrigeration appliance can be built
into any run of kitchen units and in-
stalled directly next to a kitchen fur-
niture housing unit. The appliance front
must protrude in front of furniture fronts
by at least 34 mm* at the sides and by
at least 55 mm* in the middle. This en-
ables the appliance door to be opened
and shut without being obstructed. To
match the height of the rest of the kit-
chen units, the refrigeration appliance
can be fitted with a suitable top box
.
When installed next to a wall
, a dis-
tance of at least 55 mm must be main-
tained on the hinge side between the
wall
and the refrigeration appli-
ance
.
The larger the ventilation gap, the
more economically the compressor
will work.
– A ventilation gap of at least 50 mm
depth must be provided at the back
of the refrigeration appliance behind
the whole width of the top box for air
to circulate.
– The ventilation gap under the ceiling
must be at least 300 cm
2
to ensure
that warm air can escape without ob-
struction.