Electrical connection
58
Risk of damage from incorrect
connection.
Incorrect installation, maintenance
and repairs can be dangerous to
users.
Miele cannot be held liable for
damage or injury caused by
unauthorised installation,
maintenance or repair work, or by an
inadequate or faulty on-site earthing
system (e.g. electric shock).
The cooktop must be connected to
the power supply by a qualified
electrician.
The electrician must be familiar with
and comply with the national
regulations and any additional
regulations of the local electricity
provider.
After installation, ensure that all
electrical components are shielded
and cannot be accessed by users.
Connection
AC 230 V, 50 Hz
The voltage and rated load are given on
the data plate. Please ensure these
match the household mains supply.
Connection must be made via a
suitable isolator switch which provides
disconnection on all poles and which
complies with national and local safety
regulations. When switched off there
must be an all-pole contact gap of at
least 3 mm in the isolator switch. The
isolator switch must be easily
accessible after the appliance has been
built in.
Please see the wiring diagram for
connection.
Residual current device
For extra safety, it is advisable to
protect the appliance with a suitable
residual current device (RCD) with a trip
range of 30 mA.
Disconnecting devices
Connection must be made via a
suitable isolator switch which provides
disconnection on all poles and which
complies with national and local safety
regulations. When switched off there
must be an all-pole contact gap of at
least 3 mm in the isolator switch. The
isolator switch must be easily
accessible after the appliance has been
built in.