Installation
-
I
N
-
S
T
A
L
L
-
A
-
T
I
O
N
-
66
Risk of damage due to condens-
ation on external appliance panels.
In environments with high humidity,
condensation can build up on ex-
ternal appliance panels, which can
cause corrosion.
To prevent this, it is advisable to in-
stall the refrigeration appliance in a
dry and/or air-conditioned room with
sufficient ventilation.
After installation, make sure that the
appliance door closes properly, that
the specified ventilation gaps are ad-
hered to, and that the refrigeration
appliance has been installed in ac-
cordance with these installation in-
structions.
Climate range
The appliance is designed for use within
a certain climate range (ambient tem-
peratures) and should not be used out-
side this range. The climate range of the
appliance is stated on the data plate in-
side the appliance.
Climate range
Ambient room
temperature
SN
+10 to +32 °C
N
+16 to +32 °C
ST
+16 to +38 °C
T
+16 to +43 °C
Operating in a room which is too cold
will cause the compressor to switch off
for too long, causing the internal tem-
perature in the appliance to rise with the
risk of food deteriorating and going off.
Ventilation
Risk of fire and damage due to
insufficient ventilation.
If the refrigeration appliance is not
ventilated sufficiently, the com-
pressor will run more frequently and
for longer periods. This will result in
increased energy consumption and a
higher operating temperature for the
compressor. This may, in turn, cause
damage to the compressor.
Please ensure that there is adequate
ventilation around the refrigeration
appliance.
It is essential to observe the ventila-
tion gaps given. The ventilation gaps
must not be covered or blocked in
any way.
Air at the back of the refrigeration appli-
ance gets warm.