en - Installation and planning notes
171
Installation requirements
The flatwork ironer must only be set up by a Miele authorised and
trained service technician or an authorised dealer.
This flatwork ironer must be installed in accordance with all relev-
ant regulations and standards. Local energy supplier regulations must
also be observed.
This flatwork ironer must only be operated in a room that has suffi-
cient ventilation and which is frost-free.
Storage
The following conditions must be observed for transport and storage
of this flatwork ironer:
- Ambient temperature: -25 °C to +55 °C
- Humiditiy: 5 % to 75 %, non-condensing
- Maximum storage period: 2 years
Operating conditions
In general, the operating conditions of DIN 60204 and EN 60204-1
apply.
- Ambient temperature: +5 °C to +40 °C
- Humidity: 10 % to 85 %
- At 21 °C ambient temperature, the maximum permissible relative
humidity is 70 %.
This ironer should not be operated in the same room as dry-
cleaning equipment using perchloroethylene or solvents containing
CFCs.
Collector motor sparking may convert solvent vapours into hydro-
chloric acid which can lead to consequential damage.
Ensure adequate ventilation is present in the room in which the
ironer is installed whilst it is being used.