Installation
*INSTALLATION*
50
Setting the gas pressure
The gas pressure must be set by the
authorised gas fitter as shown on the
data plate:
Natural gas 1.0 kPa
ULPG (Propane/Butane) 2.75 kPa
The gas pressure must be set with the
largest burner operating at maximum
setting.
For ULPG models
a
b
~ 60
a
Connection R ¹/₂" with test point
b
Connection R ¹/₂" with test point and
90° angle
When using a 90° angle the building-
in depth will increase to the depth of
the elbow used.
For natural gas models
The gas regulator is only included with
appliances which are set up for
connection to natural gas. The
regulator must be connected directly
to the appliance.
a
a
Pressure Test Point
Loosen the screw in the test point
until it is free in its housing. The
screw is retained in this position.
Connect the hose from the pressure
gauge.
Reassemble one of the large burners,
turn on the gas and manually light the
burners.
Disconnect the hose from the
pressure gauge and screw in the test
point screw.
For natural gas models: Connect the
gas regulator directly to the
appliance.
Summary of Contents for ProLine CS 1013-1
Page 41: ...Installation INSTALLATION 41 Distances from burner to the edge of the appliance ...
Page 57: ......
Page 58: ......