Washing without dispenser compartment
25
Dispenser calibration
Dispensing calibration is used to measure the throughput of individual
dispensing pumps.
To go directly to
"dispenser calib-
ration" when the
machine is
switched off:
Press and hold multifunction button 2 and switch the machine on
with Power on
.
Dispenser calibration
Main menu
Dispenser pump 1
Dispenser pump 2
Options:
– Dispenser pump 1 to 13
Select a dispenser pump.
When a dispenser pump is selected, the following will appear in the
display:
Dispenser calibration
Dispenser pump 1
V:
100 ml
0/1
0s
t:
P:
No
Tip:
The dispensing amount can be set from 0 to 9999 ml in 1 ml in-
crements.
Press multifunction button 0/1.
The dispensing hose will fill up.
Stop the process by pressing button 0/1.
Run the hose of the dispenser pump that is being checked upwards
into a measuring vessel.
Irritant agents.
Skin and eye irritation.
Avoid contact with skin and eyes, wear protective clothing.
Return to the main menu by pressing
"Back".
Dispenser calibration
Main menu
Dispenser pump 1
Dispenser pump 2
Select a dispenser pump.