Washing without dispenser compartment
26
Dispenser calibration
Dispenser pump 1
0/1
0 s
t:
P: No
V:
100 ml
Press multifunction button 0/1.
Stop the pump by pressing button 0/1, or the pump will stop auto-
matically after 60 seconds.
Measure the required amount in the measuring vessel.
Dispenser calibration
Dispenser pump 1
0/1
30 s
t:
P: 200 ml/min
V:
100 ml
Enter the amount measured in field "V:".
The throughput P is calculated in ml/min. by the controls.
Press the "Save"
button.
The measured value is assigned to the pump.
Reattach the hose.