Installation and connection
81
Dispensing agent connection to the liquid dispensing
mixing compartment
Connections
1
and
2
are provided for viscous agents. These con-
nections are sealed and need to be drilled open using an 8 mm drill
bit.
Care must be taken to drill through the first wall (1) only, as there is a
deflecting wall (2)10 mm behind it.
If the drilled out connections are no longer required, they must be re-
sealed.
Connections
3
to
12
are provided for liquid dispensing. These con-
nections are sealed and must be cut to suit the diameter of the hose
with a suitable hacksaw. If opened connections are no longer re-
quired, they must be resealed.
Water drainage
AV
machines: DN 70 on the machine, DN 70 sleeve on-site. Through-
flow rate 200 l/min.
If the slope for drainage is extremely steep, the piping must be vented
to prevent formation of a vacuum in the machine's drain system.
Foam and vapour venting kit
BWS
If excessive suds form, foam may escape from the vapour vent. To re-
move the foam, an optional vapour venting kit (BWS) can be used.