Installation and connection
83
Emergency
switch-off
For washing machines without a separate emergency off switch,
there must be a central emergency shut-off at the installation site!
The emergency switch-off puts the machine into a safe state in the
event of danger or in order to prevent danger. The emergency switch-
off must be placed in such a way that the user can activate it immedi-
ately in an emergency.
If it is necessary to install a residual current device (RCD) in ac-
cordance with local regulations, a residual current device type B
(sensitive to universal current) must be used.
An existing type A residual current device, (RCD) must be exchanged
for a type B RCD.
If necessary, equipotential bonding with good galvanic contact
must be guaranteed in compliance with all applicable local and na-
tional installation specifications.
Equipotential bonding must have an earth current rating > 10 mA
Accessories for equipotential bonding are not supplied and need to
be ordered separately.
Connecting the dispensing pumps
Connection terminals for 4 time-controlled dispenser pumps, which
can be operated without a multifunction module, are located behind
the cover adjacent to the electrical connection. See enclosed wiring
diagram.
Once the machine has been successfully installed and connected,
replace all the housing parts that were removed.