Technical Datasheet
Washer-extractor:
Heating:
PW 6080 AV/LP
Electric (EL)
Legend:
Circled, bold-type abbreviations:
Connection required
Abbreviations surrounded by broken circle:
Connection optional or required, depending on model
Optional extras:
UM
Miele plinth
UO 6008 (UO = Open plinth)
Height
mm
305
Width
mm
680
Depth
mm
679
UG 6008 (UG = Closed plinth)
Height
mm
305
Width
mm
692
Depth
mm
685
US 6008 (US = Plinth with drawer)
Height
mm
320
Width
mm
692
Depth
mm
685
BS
Concrete plinth
Concrete plinth (min. quality C12/15)
Recommended height
mm
300
Minimum height
mm
70
Recommended width
mm
≥700
Recommended depth
mm
≥700
It must be ensured that the om-site concrete plinth is
anchored to the floor!
Machine connections:
Electrical
connection
1. Standard voltage (as supplied)
V
3N AC 400
Frequency
Hz
50
Rated load
kW
8.2
Fuse rating
A
3 × 16
Connection cable cross-sectional area
mm²
5 × 1.5
Connection cable length
mm
2000
Connection cable without plug
(supplied as standard)
Country variations:
1. Standard voltage (as supplied)
V
1N AC 220 - 240
Frequency
Hz
50
Rated load
kW
5.05 – 6.0
Fuse rating
A
1 × 25
Connection cable cross-sectional area
mm²
3 × 2.5
Connection cable length
mm
2000
Connection cable without plug
(supplied as standard)
1. Standard voltage (as supplied)
V
3 AC 230
Frequency
Hz
50
Rated load
kW
8.2
Fuse rating
A
3 × 20
Connection cable cross-sectional area
mm²
4 × 2.5
Connection cable length
mm
2000
Connection cable without plug
(supplied as standard)