background image

 

Technisches Datenblatt / Technical datasheet: PW 6080 EL AV/LP 
Datum / Date: 28.10.2009 

  Seite / Page: 9 

 

 

 

Non-standard voltages:

 

 

OS 440 

1. Standard voltage (as supplied)

 

 

3 AC 440 

 

Frequency

 

 

Hz 

60 

 

Rated load

 

 

kW 

7.9 

 

 

Fuse rating

 

 

3 × 16 

 

 

Connection cable cross-sectional area 

 

mm² 

4 × 1.5 

 

 

Connection cable length 

 

mm 

2000 

 

 

Connection cable without plug 
(supplied as standard) 

 

 

 

 

 

Electrical connection must be in accordance with local and 
national regulations. 

Plug and socket connection in accordance with IEC/EN 
60309 and IEC/EN 60947 recommended to facilitate 
electrical safety tests. 
If the machine is connected via a fixed connection, a multi-
pole switch must be provided on site to ensure complete 
isolation. Switches with a contact opening of more than 3 mm 
should be used. Such switches are, e.g., LS switches, fuses 
and contactors (IEC/EN 60947). 
A wall socket or mains isolator must be visible and accessible 
after installation. 

A new connection, modification of an existing installation or 
earth checking, including the determination of suitable fuse 
rating, may only be carried out by a suitably qualified 
electrician in accordance with all local and national 
regulations. 

 

 

 

Cold water 

(soft water) 

Min. flow pressure 

kPa 

100 

Max. pressure 

kPa 

1000 

Max. throughput 

l/min 

11 

 

 

On-site connection thread according to DIN 44 991 

Inch 

¾" external thread 

 

 

Length of connection hose  
(parts supplied: 1 connection hose) 

mm 

1550 

 

 

Water requirements (average for 60°C programme) 

 

 

 

 

With standard connection (with hot water) 

l/h 

Approx. 70 

 

 

If hot water supply is not available, a sufficient supply of cold 
water must be ensured. 

 

 

 

 

If connected to an alternative water supply (optional), subtract 
cold water volume. 

 

 

 

Hot water 

(soft water) 

Max. temperature 

°C 

70 

Min. flow pressure 

kPa 

100 

Max. pressure 

kPa 

1000 

 

 

Max. throughput 

l/min 

11 

 

 

On-site connection thread according to DIN 44 991 

Inch 

¾" external thread 

 

 

Length of connection hose  
(parts supplied: 1 connection hose) 

mm 

1550 

 

 

Water requirements (average for 60°C programme) 

l/h 

Approx. 70 

 

 

It is possible to connect the machine to a very hot water 
supply with temperature from 70°C to max. 85°C. For this a 
special connection hose is required. This special hose is 
available from the Miele Spares Dept. 
In addition, the Miele Service Dept. or an authorised dealer 
must reprogram the machine accordingly. 

 

 

 

 

If a hot water supply is not available, connect the hot water 
hose to a cold water supply! 

 

 

 

Alternative water 

supply 

(Optional) 

Min. flow pressure 

kPa 

100 

Max. pressure 

kPa 

1000 

Max. throughput 

l/min 

11 

 

On-site connection thread according to DIN 44 991 

Inch 

¾" external thread 

 

 

Length of connection hose  
(parts supplied: 1 connection hose) 

mm 

1550 

 

 

Water requirements (average for 60°C programme) 

l/h 

Not yet available 

 

Summary of Contents for PW 6080 EL AV

Page 1: ...11 09 Mat no 07 780 680 01 Installation recommendations Washer extractor PW 6080 EL AV LP en GB ...

Page 2: ... no 07 780 680 01 2 It is essential to read the operating and installation instructions before installing commissioning or using the machine This avoids the risk of accidents or damage All rights reserved ...

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ... width mm 700 Recommended depth mm 700 It must be ensured that the om site concrete plinth is anchored to the floor Machine connections Electrical connection 1 Standard voltage as supplied V 3N AC 400 Frequency Hz 50 Rated load kW 8 2 Fuse rating A 3 16 Connection cable cross sectional area mm 5 1 5 Connection cable length mm 2000 Connection cable without plug supplied as standard Country variatio...

Page 9: ... 11 On site connection thread according to DIN 44 991 Inch external thread Length of connection hose parts supplied 1 connection hose mm 1550 Water requirements average for 60 C programme With standard connection with hot water l h Approx 70 If hot water supply is not available a sufficient supply of cold water must be ensured If connected to an alternative water supply optional subtract cold wate...

Page 10: ... 4 fasteners to secure machine to plinth 4 screws DIN 571 Ø length mm 6 50 4 rawl plugs Ø length mm 8 40 Machine must be bolted to the floor Fixing materials for floating screed floor to be provided on site On concrete plinth 2 metal brackets 2 screws DIN 571 Ø length mm 6 50 2 rawl plugs Ø length mm 8 40 Machine must be bolted to the floor Fixing materials for floating screed floor to be provided...