background image

 

Installation plan PW 6131 Steam 

Date 19.10.2007 

 Page 

 

 

 
 

Technical datasheet 

 

 

 

 

 

 

Washer:  
Heating: 
 

 PW 6131 
 Steam 

 

 Legend: 

 

Circled, bold-typed abbreviations: 
Connection required 

 

 

 

Abbreviations surrounded by broken circle: 
Connection optional or required, depending on model 


V

 

 

Options/Accessories: 
 

UG/UO 6013 

 

 

Miele plinth  

(UG = Box plinth/UO = Open plinth) 

 

 

UM 

 

Height Model 

5  11/16" 

144 mm 

 

 

Width UG (UO) 

31  1/2" (30 11/16") 

800 (780) mm 

 

 

Depth UG (UO) 

37"  (35 3/8") 

939  (899) mm 

Concrete platform  Concrete platform optional (min. Quality B15) 

 

 

 

Recommended height 

5  7/8" 

150 mm 

BS 

 

Minimum height 

4" 

100 mm 

 

 

Recommended width 

35  7/16" 

900 mm 

 

 

Recommended depth 

39  3/4" 

1.010 mm 

 

 

Ensure good anchorage! 

 

 

WI 

Special product 

With integrated scale 

 

 

 

 

Machine connections: 
 

 

Electrical 

connections 

 

USA CDN 

Standard voltage (factory set) * 

3 AC 220-240 V 

3 AC 220-240 V 

Frequency 

50-60 Hz 

50-60 Hz 

Rated load 

2.3 kW 

2,3 kW 

Fuse rating 

3 × 15 A 

3 × 15 A 

Supply lead, wire size 

14 AWG 

4 × 1,5 mm² 

* If power supply includes a stinger leg,  
please call Technical Service at  
USA 1-800-991-9380 
CDN 1-800-643-5361 

 

 

 

Alternative voltage  

3 AC 208 V 

3 AC 208 V 

Frequency 

60 Hz 

60 Hz 

Rated load 

2.3 kW 

2,3 kW 

Fuse rating 

3 × 15 A 

3 × 15 A 

Supply lead, wire size 

14 AWG 

4 × 1,5 mm² 

 

 


V

 

 

rev

e

rs

ib

le

 

 

 

Summary of Contents for PW 6131 D

Page 1: ...anta di installazione Plano de instalación Plano de instalação Σχέδιο εγκατάστασης Asennusohje Installasjonsplan Installationsplan UV PW 6131 D Materialnummer Mat no 06 563 440 Änderungsstand Version 01 Datum Zeichnung Drawing date 19 10 2007 Datum Legende Legend date 19 10 2007 ...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ...15 Recommended height 5 7 8 150 mm BS Minimum height 4 100 mm Recommended width 35 7 16 900 mm Recommended depth 39 3 4 1 010 mm Ensure good anchorage WI Special product With integrated scale Machine connections Electrical connections USA CDN Standard voltage factory set 3 AC 220 240 V 3 AC 220 240 V Frequency 50 60 Hz 50 60 Hz Rated load 2 3 kW 2 3 kW Fuse rating 3 15 A 3 15 A Supply lead wire si...

Page 9: ...sure 14 5 psi 14 5 psi Max pressure 145 psi 145 psi Cold water Soft water Max throughput if hot water supply is not available 6 9 11 gal min 26 42 l min On site connection thread 3 4 MPT 3 4 MPT Length of connection hose supplied 2 hoses and Y adapter 59 1 16 1 500 mm Water requirements average 140 F 60 C program Standard connection with hot water connection 27 5 gal h approx 104 l h Additional re...

Page 10: ... Without plinth 2 screws Diameter length 5 16 x 3 1 8 8 80 mm 2 wall anchors Diameter length 1 2 x 2 3 8 12 60 mm Machine must be secured Fixing materials provided for securing to concrete floor On concrete platform 4 screws Diameter length 5 16 x 3 1 8 8 80 mm 4 wall anchors Diameter length 1 2 x 2 3 8 12 60 mm Machine must be secured Fixing materials provided for securing to concrete floor Witho...