Indirect steam (page 4) 

 

 

Steam pressure 

87 - 145 psi 

87 - 145 psi 

Steam pressure on dryer version 

58 - 72 psi 

58 - 72 psi 

Boiling point 

306 - 363 °F 

152 - 184 °C 

Heating capacity 

37 kW 

37 kW 

 

Steam 

connection 

Steam supply capacity 

147 lbs/h 

67 kg/h 

 

 

Connection thread (on-site) 

1/2" MPT 

1/2" MPT 

 

 

Steam valve, steam filter and steam faucet must be 
provided on-site. 

 

 

 

 

Direct steam (page 5) 

 

 

 

 

Steam pressure (High pressure) 

 58 psi 

 58 psi 

 

 

Boiling point (High pressure) 

 306 °F 

 152 °C 

 

 

Heating capacity (High pressure) 

26 kW 

26 kW 

 

 

Steam supply capacity (High pressure) 

101 lbs/h 

46 kg/h 

 

 

Steam pressure (Low pressure) 

 

7.25 psi 

 

7,25 psi 

 

 

Boiling point (Low pressure) 

 

84 °F 

 

120 °C 

 

 

Heating capacity (Low pressure) 

18 kW 

18 kW 

 

 

Steam supply capacity (Low pressure) 

68 lbs/h 

31 kg/h 

 

 

Connection thread (on-site) 

1/2" MPT 

1/2" MPT 

 

 

Steam valve, steam filter, steam faucet and non-return 
valve must be provided on-site. 

 

 

 

 

Note installation instructions for steam-heated Miele 
washer-extractors.  

 

 

Condensate 

connection 

Indirect steam (page 4) 

Connection thread (on-site) 
 

 

1/2" MPT 

 

1/2" MPT 

 

 

Steam valve, steam filter and steam faucet must be 
provided on-site. 

 

 

Min. flow pressure 

14.5 psi 

14,5 psi 

Max. pressure 

145 psi 

145 psi 

 

Cold water 

(Soft water) 

Max. throughput (if hot water supply is not available) 

6.9 (11) gal/min 

26 (42) l/min 

 

 

On-site connection thread 

3/4" MPT 

3/4" MPT 

 

 

Length of connection hose  
(supplied: 2 hoses and Y adapter) 

59 1/16" 

1.500 mm 

 

 

Water requirements (average 140°F [60°C] program) 

 

 

 

 

Standard connection (with hot water connection) 

27.5 gal/h 

approx. 104 l/h 

 

 

Additional requirements if hot water supply is not 
available. 

 

 

Max. temperature 

158 °F 

70 °C 

Min. flow pressure 

14.5 psi 

14,5 psi 

 

Hot water 

Max. pressure 

145 psi 

145 psi 

 

 

Max. throughput  

4.2 gal/min 

16 l/min

 

 

 

On-site connection thread 

3/4" MPT 

3/4" MPT 

 

 

Length of connection hose (supplied) 

59  1/16" 

1.500 mm 

 

 

Water requirements (average for 140°F [60°C] program)   

 

 

 

Standard connection (with hot water connection) 

approx. 30 gal/h 

 approx. 98 l/h 

 

 

If no hot water supply, connect hose to cold water! 

 

 

Min. flow pressure 

14.5 psi 

14,5 psi 

Max. pressure 

145 psi 

145 psi 

 

Max. throughput  

8.45 gal/min  

32 l/min 

 

Mains water 
(Raw water) 

(Optional) 

On-site connection thread 

3/4" MPT 

3/4" MPT 

 

 

Length of connection hose  
(supplied: 2 hoses and Y adapter) 

59 1/16" 

1.500 mm 

 

 

Water requirements (average for 140°F [60°C] program)   

 

 

 

Standard connection (with hot water connection) 

approx. 16.4 gal/h 

approx. 62 l/h 

 

 

If connected to raw water supply, subtract cold water 
(soft) volume. 
 

If no raw water supply, connect hose to cold water! 

 

 

Summary of Contents for PW 6131 D

Page 1: ...anta di installazione Plano de instalación Plano de instalação Σχέδιο εγκατάστασης Asennusohje Installasjonsplan Installationsplan UV PW 6131 D Materialnummer Mat no 06 563 440 Änderungsstand Version 01 Datum Zeichnung Drawing date 19 10 2007 Datum Legende Legend date 19 10 2007 ...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ...15 Recommended height 5 7 8 150 mm BS Minimum height 4 100 mm Recommended width 35 7 16 900 mm Recommended depth 39 3 4 1 010 mm Ensure good anchorage WI Special product With integrated scale Machine connections Electrical connections USA CDN Standard voltage factory set 3 AC 220 240 V 3 AC 220 240 V Frequency 50 60 Hz 50 60 Hz Rated load 2 3 kW 2 3 kW Fuse rating 3 15 A 3 15 A Supply lead wire si...

Page 9: ...sure 14 5 psi 14 5 psi Max pressure 145 psi 145 psi Cold water Soft water Max throughput if hot water supply is not available 6 9 11 gal min 26 42 l min On site connection thread 3 4 MPT 3 4 MPT Length of connection hose supplied 2 hoses and Y adapter 59 1 16 1 500 mm Water requirements average 140 F 60 C program Standard connection with hot water connection 27 5 gal h approx 104 l h Additional re...

Page 10: ... Without plinth 2 screws Diameter length 5 16 x 3 1 8 8 80 mm 2 wall anchors Diameter length 1 2 x 2 3 8 12 60 mm Machine must be secured Fixing materials provided for securing to concrete floor On concrete platform 4 screws Diameter length 5 16 x 3 1 8 8 80 mm 4 wall anchors Diameter length 1 2 x 2 3 8 12 60 mm Machine must be secured Fixing materials provided for securing to concrete floor Witho...

Reviews: