Technical Information
68
T1302, T1303, T1322, T1329ci, T1323c,
T1403 and T1405 Clothes Dryers
Test Step Service Level 2 – Activation and Navigation
The
Test Step
is indicated by a flashing Drying LED.
While in Service Level 2 press the
Start Button
to begin the first
Function Test.
Press the
Start Button
to advance to the next Function Test. .
Turn the unit off to quit the test mode.
Table 060-3:
Service Mode (continued on Table 060-4)
TEST STEP
Flashing
Drying LED
SERVICE
LEVEL
Flashing
Buzzer LED
SERVICE
FUNCTION
Long
Short
Function Tested/
Machine Response
–
ROM ID code
X
Y
ROM ID code XY
–
–
No faults registered
– 2
F2 = NTC Temperature
sensor – Heater bank
(2R30)
–
4
F4 = NTC Temperature
sensor – Drum Support
Housing (1R30)
4
1
F41 = Model type changed
(vented / condenser) or
EEPROM fault
1
To display a stored fault -
Press the Start button.
To view additional stored
fault(s) - Press the Start
button again.
To delete fault(s) - Press and
Hold the Start button for at
least 5 seconds.
5
5
F55 = Program time limit