background image

WIRELESS VEHICLE DETECTION AT ITS BEST!!!

800-473-0213        ~        info@mierproducts.com        ~        www.mierproducts.com

600/605-Q22021

1

2

3

3

4

5

DA-600

DA-605

Page(s) 

Content                                                                                             

2-3  

DA-600 and DA-605

 Control Panel/Receiver Installation Guide

4-6 

 

Sensor/Transmitter Installation Guide

 

Installation Tips

 

Hooking Up Other Equipment to your Control Panel/Receiver

9   Accessories

10 

 

Long Range Installations

11 

 

Supplemental Specifications

12   Troubleshooting

13 

 

Technical Support Information and Warranty

1)  A sensor(s) detect(s) a vehicle entering monitored 
      area(s) . 
2)  A control panel up to 1000 feet away receives a 
      signal from the sensor and triggers an alert inside 
      the home or business (booster antenna increases 
      range to 3/4-mile)

3)  Add remote plug-in chimes in the  front room, 
     basement, upstairs, back yard, by the pool, or in 
     other buildings
4)  Add a Timer Control to turn on outdoor and in
     door lights to warn strangers or welcome friends
5)  Activate video surveillance to record activity and 
     display the driveway on a monitor
6)  Activate signs, gates, alarm panels or other 
     equipment
7)  Add a repeater to send the signal another 1000’ 
     to rrigger additional alerts in out buildings, or 
     add a booster-antenna for buildings up 3/4-mile 
     away

THE BASICS

MORE OPTIONS

Summary of Contents for DA-600

Page 1: ...ering monitored area s 2 A control panel up to 1000 feet away receives a signal from the sensor and triggers an alert inside the home or business booster antenna increases range to 3 4 mile 3 Add remote plug in chimes in the front room basement upstairs back yard by the pool or in other buildings 4 Add a Timer Control to turn on outdoor and in door lights to warn strangers or welcome friends 5 Act...

Page 2: ...allations page Use of an unlimited number of Mier Wireless Transmitters by a Control Panel Receiver 100 compatibility with the Mier DA 610TO optional DA 611TO and optional DA 612TO Sensor transmitters Compatible with Mier Accessories detailed in this manual See Accessories Page EASY INSTALLATION IS OFTEN COMPLETED IN UNDER 30 MINUTES Plug In the Plug In or Place the Place the Sensor Control Panel ...

Page 3: ... is to be mounted indoors 4 6 feet above ground level where 110 volts AC power is available To maximize transmitter reception the flexible antenna is to be at least 12 inches from any metal pipes power conduits breaker boxes etc Simply plug the Control Panel Receiver into a standard wall outlet where the signal from the Sensor Transmitter can reach it For extended mile range reception or when a Co...

Page 4: ...ivity in the driveway See next two pages for directions Lightning strikes cause a large disturbance in the magnetic field so nearby strikes will cause an alarm It is also possible for electrical current variations in nearby power lines to cause an alarm The address codes for these Sensor Transmitters as well as the Control Panel Receivers are pre set at the factory However if a unique address code...

Page 5: ... layer of silicone oil on the underside of the cover Failing to do either will result in moisture entering the enclosure The Sensor Transmitter can now be placed in position For maximum range the black box Transmitter portion of the DA 610TO DA 611TO or DA 612TO should be placed 3 to 4 feet above ground on a post tree etc The front of the Transmitter Box should also face the Control Panel Receiver...

Page 6: ...an one Zone is to be monitored place jumpers on the Zone Pins on the electrical board in the black box to active them AND pull the jumper off of the JP3 Jumper Pin inside the white DA 700 or DA 100 Control Panel The Drive Alert will give a different Chime tone for each Zone monitored This photo of the Transmitter board inside the black box shows where to place the batteries turn it On see the Vali...

Page 7: ... STABLE AND MOTIONLESS Any movement of the sensor will cause an alarm Don t mount the Sensor on a tree post or gate that might move in the wind DO NOT mount the Sensor where it might be near underground or above ground power lines Power surges in the sensor area will cause false alarms DO NOT bury the Transmitter Box in the ground DO NOT install the Transmitter Box in an Aluminum Copper or Steel e...

Page 8: ...d to the GND terminal will operate the Drive Alert Therefore the Control Panel Receiver can become portable the sensor is always portable so the unit can be used in a vehicle or at a remote site NOTE DO NOT PLUG THE UNIT INTO 110 VAC IF ALSO OPERATED ON BATTERY AS IT CAUSES FAILURE SIG ALA 5VDC GND 24DC NO NC C NO C Connecting Line of Sight Wireless Transmitter such as Mier s DA 606LK Light Kit Th...

Page 9: ...10 Sensor HARD WIRED DRIVE ALERT ACCESSORIES DA 655 DA 500LKA DA 052V DA 505 DA 505W DA 050 The Hard Wired DA 655 Chime with Volume Control is our most popular accessory for the model DA 500 Drive Alert in Drive up Window or business applications The DA 500LKA is a set of Form C Dry Contacts that can be attached to the DA 700 or DA 500 Control Panels The DA 052V Whistle with Volume Control used wi...

Page 10: ... is actually a self contained Control Panel Receiver on its own and receives a signal from up to 1000 feet from any of Mier s wireless Sensor Transmitters OR a DA REPEATER shown above and provides a pleasant tone as an alert It also includes volume control The DA 611TO and DA 612TO Sensor Transmitters increase transmission distance The Sensor s is are outside the Transmitter Box and attached to th...

Page 11: ...rized by Mier Products Inc may void the user s authority to operate this equipment IC ID 5583ADA 066MP Cet appareil est conforme a des reglements d industrie Canada exempts de license standard RSS s Son fonctionnement est soumis aux deux conditions 1 Ce dispositif ne doit pas causer d interferences nuisibles 2 Cel appareil doit accepter toute interference recue y compris les interferences pouvant ...

Page 12: ...Tech Support They will work with you and might recommend returning the system to Mier Products for diagnosis and repair Panel is quiet replace the accessory Check the sensor transmitter placement 50 min away from the street power phone lines Move sensor or reduce sensitivity Existing New Accessory Defective OK OK OK Still Not Fixed Existing New OK Check the batteries Power is ON TX_TEST is OFF SW1...

Page 13: ...tallation instructions Drive Alert accessories and parts built by other OEMs including but not limited to chimes lamp modules light switches bells splice kits are covered under their respective OEM warranties This warranty constitutes the entire warranty with respect to Mier s Drive Alert Models and Accessories and IS IN LIEU OF ALL OTHERS EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OR MERCHANTABI...

Reviews: