16
BA_Lötstar_EN_Vers.07.2016
© MIG·O·MAT GmbH
5.2
Mounting of the unit top part
The preassembled unit top part is packed separately and must
be mounted onto the Lötstar base unit. The protecting foil
remain around the glass containers (serves as fracture
protection).
Risk of injury splintering glass!
Combustion of gas inside the glasses due to gross disregard of
the safety instructions can cause the glasses to burst.
Do not operate the unit without protective the hood (
illustration
5.2.E
.) over the glasses.
After replacing either one or both of the glasses, pull the
protective hood(s) over the new glass(es).
•
1 fork wrench size 10 mm (or comparable, suitable tool).
•
1 fork wrench size 19 mm (or comparable, suitable tool).
Illustration 5.2. Correctly mounted and connected unit top part
1. Use the 4 cap nuts (A) to screw the unit top part to the 4
threaded bolts on the Lötstar unit top (fork wrench 10 mm).
2. Remove the yellow screw cap (transport safety device) on
the reactor outlet (B). Please keep the yellow screw cap for
possible future service purposes.
3. Connect the gas hose to the reactor outlet by means of the
union nut (fork wrench 19 mm).
Caution!
Do not jam the
connection nut.
Then tighten the connecting nut by means of the fork
wrench. For this, hold the reactor at the filling duct with one
hand. A slight movement of the reactor is possible and
harmless because the reactor connection is elastic. Tighten
WARNING
Required tools
How to proceed
A
A
B
C
D
E