background image

 

- 23 - 

L I S E D

T

CM

C

US

Intertek

Conforms to ANSI STD Z83.11-2016

Certified to CSA STD 1.8-2016

LI S

ED

T

CM

Intertek

4003935

Conforms to NSF/ANSI STD.4

S

A

N I T

AT I ON

 

 
 
 
 

Our products have the advantages of good durability and low maintenance 

charge. But to update some components and necessary maintenance, can prolong 
life length of the products. Contact the dealer for assistance. In order to avoid 
confusion, please follow the format in figure 10 and table 4. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Migali

 Industries,  Inc.   

      Trusted  Since  1955  
 
      516 Lansdowne Ave  
      Camden, NJ 08104 
      Service Call: 800.852.5292 
      Service Email: warranty@mgiali.com

 

 

Summary of Contents for C-SPS-1-18-LP

Page 1: ...ing Instructions Before you begin please read these instructions carefully to use this product correctly to make the product perform ideally and to avoid hazards Models C SPS 1 18 NG LP C SPS 2 18 NG LP C SPS 1 18L NG LP C SPS 2 18L NG LP ...

Page 2: ...manual in a safe place for convenient reference and operation This instruction manual is subject to any change without further notice and the manufacturer reserves the right of final interpretation The appliance is designed for commercial purposes not for household use A statement instructing the purchaser to post in a prominent location instructions to be followed in the event the user smells gas...

Page 3: ...3 2 Brief Introduction 3 3 Manufacturer s Authority and Responsibility 3 4 Parameter Specifications 4 5 Transport and Storage 6 6 Installation and Debugging 6 7 Safety Notices and Precautions 8 8 Operating Instructions 9 9 Cleaning and Maintenance 11 10 Troubleshooting 12 11 Spare Parts 14 12 Accessories List 18 ...

Page 4: ... lack the necessary knowledge or experience unless with appropriate instructions and sufficient safety 2 Brief Instruction The product is a series of gas char broilers in our company production which is novel designed reasonable structured convenient operated durable used and convenient maintained It s equipped with a cast iron burner and a high efficiency stainless steel tubular burner and a pilo...

Page 5: ...icians Use the spare parts or accessories provided by non manufacturers Accidents caused by force majeure Not strictly comply with related guide of this instruction by any reason 4 Parameter Specifications 4 1 Outline Dimensions in C SPS 1 18 NG LP ...

Page 6: ... 5 C SPS 2 18 NG LP ...

Page 7: ... 6 C SPS 1 18L NG LP ...

Page 8: ...2 18L NG LP 4 2 Information of Gas Supply and Burner The minimum supplied gas pressure regulator is factory set at 4 Natural Gas W C and 10 L P Gas W C The external thread of product s intake tube is 3 4 inches ...

Page 9: ...should not be in open air for a long time and shall be placed in a well ventilated and non corrosive gases warehouse When equipment needs temporary storage rainproof measures should be taken 6 Installation and Debugging Any erroneous installation adjustment refit overhaul or maintenance may cause property damage or personal injury The work shall be performed by authorized and licensed technicians ...

Page 10: ... ventilation laws and codes are very different you should state and comply with all codes of the National Fire Protection Association Inc when it comes to requirements for installation of equipment Screw 4 adjustable stainless steel legs in the tapping hole with four corners of the charbroiled bottom ensure sufficient space for ventilation Adjustable stainless steel legs to make the equipment leve...

Page 11: ... to bargain Unplug pressure gauge after you accomplish pressure testing then install needle type pressure joint screw arbor Important must screw joint screw arbor to prevent gas escape 6 2 Debugging It s very important to debug the new stove Through the comprehensive system test of equipment we can ensure function and safety performance of products Discovering any potential problems before use suc...

Page 12: ...hout authorization Never change any other parts without authorization to this equipment otherwise may cause hazards and the manufacturer has the right not to provide warranty service Steel cutting producers used to manufacture with sharp edges The manufacturer has dealt with these sharp edges during production however we insist the operator take care when in contact with this piece of equipment Al...

Page 13: ...ront burner Back burner Back burner control knob control knob outer ring inner ring outer ring inner ring control knob control knob control knob control knob Fig 5 Fig 6 Reminder Turn on the knob controlling inner ring burner first then turn on the main fire valve as shown in Fig 5 and 6 Make sure air circulation at the bottom of equipment Do not use fan or air conditioning blowing at the flame in...

Page 14: ...ing an hour 8 5 Exchange main fire nozzle to switch gas source Remove control panel cooking grates the pilot light head and burner remove main fire nozzle with proper open spanner exchange nozzle of another gas source then screw it Fig 8 Reinstall burner the pilot light head cooking grates and control panel in proper order Caution Each main fire orifice of the burner has been installed before deli...

Page 15: ...l control valves must be turned off Strictly follow the lighting instructions to work again after cleaning Warning Wait for the equipment to cool down after the unit has been turned off before you clean Cut off the gas source when not in use If the equipment is not used for a long time clean the surface by wiping it with a soft cloth and place it in a well ventilated area Comprehensively check the...

Page 16: ...y is permitted to fill too high should be cleaned Per use 10 Troubleshooting Table 3 Problems Possible causes Problem solving Not lighting 1 Insufficient gas pressure in pipe 1 Contact the local gas supply dept 2 Nozzle occlusion 2 Dredge nozzle Ignite the pilot light but not the main fire 1 Insufficient gas pressure in pipe 1 Contact the local gas supply dept 2 The main fire nozzle occlusion 2 Dr...

Page 17: ...ot enough air to ignite 3 Increase damper opening degree 4 In the peak of using gas sources of gas float heavy 4 Turn down valves flow Turn it up after the peak The problems mentioned above are only for reference If any fault occurs please stop using and contact technicians to check and repair Safety first turn off the power and gas supply before maintenance 11 Spare Parts The use of parts provide...

Page 18: ... 17 Fig 10 ...

Page 19: ...002 C SPS 2 18 NG LP 21206001002 C SPS 1 18L NG LP 21206002002 C SPS 2 18L NG LP 4 301081006 Galvanized American outside six corner with pad tapping 6 ST4 8 12 5 C SPS 1 18 NG LP 8 C SPS 2 18 NG LP 6 C SPS 1 18L NG LP 8 C SPS 2 18L NG LP 5 21106001010 Catch tray 1 460 365 13 C SPS 1 18 NG LP 21106002012 990 365 13 C SPS 2 18 NG LP 21106001010 460 365 13 C SPS 1 18L NG LP 21106002012 990 365 13 C S...

Page 20: ...1 18L NG LP C SPS 2 18L NG LP 12 301030002 A18 stopcock 2 A18 318 C SPS 1 18 NG LP 4 C SPS 2 18 NG LP 2 C SPS 1 18L NG LP 4 C SPS 2 18L NG LP 13 301040012 A18 nozzle NG32 2 C SPS 1 18 NG LP 301040013 A18 nozzle LP49 4 C SPS 2 18 NG LP 301040012 A18 nozzle NG32 2 C SPS 1 18L NG LP 301040013 A18 nozzle LP49 4 C SPS 2 18L NG LP 14 301990006 Damper cover 2 C SPS 1 18 NG LP 4 C SPS 2 18 NG LP 2 C SPS 1...

Page 21: ... 1 18L NG LP 4 C SPS 2 18L NG LP 21 211060001011 Pilot light head stator 2 C SPS 1 18 NG LP 4 C SPS 2 18 NG LP 2 C SPS 1 18L NG LP 4 C SPS 2 18L NG LP 22 21106002014 Front burner inner pilot intake tube 1 Φ4 7 0 6 C SPS 1 18 NG LP C SPS 2 18 NG LP C SPS 1 18L NG LP C SPS 2 18L NG LP 23 301080008 Brass lock nut 0 M18 C SPS 1 18 NG LP 2 C SPS 2 18 NG LP 0 C SPS 1 18L NG LP 2 C SPS 2 18L NG LP 24 301...

Page 22: ...8L NG LP 2 C SPS 2 18L NG LP 30 301010013 Boiler burner 1 Φ305 385 C SPS 1 18 NG LP 2 C SPS 2 18 NG LP 1 C SPS 1 18L NG LP 2 C SPS 2 18L NG LP 31 301070014 18 single head broiler in take tube 1 343 523 86 C SPS 1 18 NG LP 301070015 18 double head broiler in take tube 343 1053 86 C SPS 2 18 NG LP 301070014 18 single head broiler in take tube 343 523 86 C SPS 1 18L NG LP 301070015 18 double head bro...

Page 23: ...nicians to ensure interface tightness 2 The pressure regulator s have connected the maximum load of natural gas cannot exceed 6 and of LP cannot exceed 12 3 Adjustment range of the pressure regulator s is 4 6 for natural gas and 7 10 for L P 4 Screw the hex nut Fig 11 before connect air intake ensure gas mark Fig 12 on the plastic core whether match with connected gas source if not then pull out t...

Page 24: ...vantages of good durability and low maintenance charge But to update some components and necessary maintenance can prolong life length of the products Contact the dealer for assistance In order to avoid confusion please follow the format in figure 10 and table 4 Migali Industries Inc Trusted Since 1955 516 Lansdowne Ave Camden NJ 08104 Service Call 800 852 5292 Service Email warranty mgiali com ...