27
With gate in CLOSED position, turn control box power switch
to ON.
Press button on transmitter; gate should start opening. Press button
on transmitter again when gate is in desired OPEN position.
NOTE: If your gate stops and reverses before it fully openss, you
may need to increase the stall force. (See page 28)
Press and hold the “LEARN MAST LIMIT” button for 5
seconds, or until the alarm sounds.
Press button on transmitter to fully close gate. Open limit is set
upon reaching the fully closed position. Test and, if needed reset
and start over.
ON
1
2
3
2
1
1 2 3 4
ON
LEARN
MAST LIMIT
LEARN
2ND LIMIT
S3
S4
S2
OFF
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN
MAX
3
2
4
1
Control Box Settings
Setting Push-to-Open (Open) Gate Limit
(for pull-to-open go to pg. 26)
Press button on opener remote to close gate.
Hold the “LEARN MAST LIMIT” button for 10 seconds, or un-
til the alarm sounds to clear. Go back to setting open gate limit
step 1 at the top of this page.
2
3
5
1
1 2 3 4
ON
LEARN
MAST LIMIT
LEARN
2ND LIMIT
S3
S4
S2
OFF
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN
MAX
6
Resetting Open Gate Limit