5. Checking the vibrator oil (See Fig.35):
6. Checking the hydraulic oil (See Fig.36):
23
Check the hydraulic oil in every 100 hours of operation.
With the handle positioned vertically (stowed position), remove breather plug at the top of
hydraulic hand pump and check the oil for proper level (To OIL LEVEL mark)
In every 100 hours of operation, position the
machine horizontally and remove the vibrator oil
level check plug (use 14mm wrench) to see oil is
up to the port.
In every 300 hours of operation, change the vibra-
tor oil. Drain oil through level check plug hole with
the machine inclined by inserting a sleeper or the
like under the opposite side of compaction plate.
*
Lubrication oil to use: Engine oil 10W-30.
Oil Capacities: R60 Series: 0.25 Liter
100 Series: 0.35 Liter
150 Series: 0.35 Liter
In case any leakage from vibrator should be detected, check vibrator oil frequently.
NOTE:
!
To prevent dust from entering, clean the port before proceeding with the vibrator oil check.
NOTE:
!
a.
Fig.35
Fig.36
OIL LEVEL
Plug cap
Breather plug
Hand pump
Effective range of oil