4
"
D I SC R
", y o u h av e to p u s h th e b u tt o n "
VC O / D IS C R
", a t w h i ch th e d ev i c e is
s w it ch ed i n to d is crimi n a t io n mo d e a n d th e d is p l a y s h o ws "
N OR M A L D I S CR
" .
2. Working with the device in "VCO" mode
In this mode the display shows
"VCO".
Constantly shown are the level of signal in digital or
graphical appearance, the capacity of the accumulator, chosen power, the sensitivity, the level of
co – working of the sound and the working mode, as follows:
- 1
st
row to the left – the working mode –
VCO,
the chosen power
P1
or
P2
and the sensitivity of the
device –
S1, S2
or
S3.
- 2
nd
row to the left - capacity of the battery in percent: 0%-100% or time to work.
- 3
rd
row to the left – the mode and the speed of searching –
Dynamic
or
Static
. The device can work
in 8 modes of speed of searching – 4 static (for precise localization of an object) – „
Static 1
“ - „
Static
4
“, and 4 dynamic (for searching while moving) - „
Dynamic 1
“ - „
Dynamic 4
“.
„Static“
are static modes of searching, i. e., the device constantly reacts to metal located within
the range of the coil. They are suitable for localization of the precise position of an already
located metal, and one can also work in those modes permanently. The fastest one is „
Static 1“
mode, and the slowest one
- „Static 4“.
„Dynamic“
are dynamic modes of operation with different speed of searching. The difference in
these modes is in the time for automatic nullification of appeared signals, i. e., the device is
constantly additionally setting itself, but with various speed in various modes. The fastest one is
the „
Dynamic 1“
mode, and the slowest of all the dynamic modes is
„Dynamic 4“.
In these
modes, the device reacts to metal objects within the range of the coil only upon movement of the
coil above them.
- 4
th
row to the right –
„Level“
- the level of signal from the registered metal in figures – from
0 –
1000
. If there is signal of metal within the range of the coil, disturbances or influence by soil,
upon short pressing of
"ON – OFF / CLEAR",
this indication will become
"0"
. After removal
of the source of the signal from the coil range, indication will become of negative value. In order
to be nullified, you have to push again
"ON – OFF / CLEAR".
During searching above ground
surface, the indication for the level of signal hesitates
(-1... 0... +1)
or more, depending on the